My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
22525
>
2200 - Hazardous Waste Program
>
PR0539882
>
COMPLIANCE INFO PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/19/2019 9:41:11 AM
Creation date
12/19/2019 9:40:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0539882
PE
2220
FACILITY_ID
FA0016746
FACILITY_NAME
BOB MACHADO FARMS
STREET_NUMBER
22525
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
22525 S AIRPORT WAY
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Teleph ne: (209) 468-3420 Fax:(209)468-3433 Web:www.sjgov.or_/q ehd <br /> Small Qua tity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Bob Machado Farms 22525 S Airport Way, MANTECA March 11 2015 <br /> Universal Waste <br /> 706 CCR 66273.33.5 Failed to roperly manage universal waste electronic devices,CRTs or CRT glass ❑V ❑R ❑COS <br /> 707 HSC 25201.16(e) Failed to anage aerosol cans in a manner that prevents the unauthorized release of waste ❑V ❑R ❑COS <br /> 708 HSC 25201.16(f) Failed to liroperly manage containers of waste aerosol cans ❑V ❑R ❑COS <br /> 709 HSC 25201.16(g) Failed to tore used aerosol cans in an accumulation container ❑V ❑R ❑COS <br /> 710 HSC 25201.16(h)(4) No written operating procedure for aerosol can processing ❑V ❑R ❑COS <br /> 711 HSC 25201.160) Failed to ubmit or amend notification for aerosol can processing ❑V ❑R ❑COS <br /> 712 CCR 66273.34 Failed to I bel universal waste to identify type of universal waste ❑V ❑R ❑COS <br /> 713 CCR 66273.35 Stored U onsite greater than one year or was unable to demonstrate the time UW has been stored ❑V ❑R ❑COS <br /> 714 CCR 66273.36 Failed to t ain employees and maintain records on UW handling and emergency procedures ❑V ❑R ❑COS <br /> 715 CCR 66273.39 Failed to k ep complete records of each shipment of universal waste for three years ❑V ❑R ❑COS <br /> Other Violations <br /> 3010 See below Unlisted A ministration/Documentation violation ❑V ❑R ❑COS <br /> 3020 See below Unlisted T aining violation ❑V ❑R ❑COS <br /> 3030 See below Unlisted O erations/Maintenance violation ❑V ❑R ❑COS <br /> 3040 See below Unlisted R lease/Leaks/Spills violation ❑V ❑R ❑COS <br /> 3050 1 See below Unlisted A andonment/IIlegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 101 CCR 66262.12 Managed a azardous waste without a valid EPA ID number. <br /> This facility does not have valid EPA ID number to manage hazardous waste. A hazardous waste generator shall <br /> not treat, store, dispose of, ransport or offer for transportation, hazardous waste without an EPA ID number. <br /> Immediately obtain an EPA ID number to manage hazardous waste and submit evidence to the EHD. A form has <br /> been provided. A DTSC 13 8 form was filled out while on site. <br /> This is a minor violation. <br /> 103 CCR 66262.34(d)(2) No mo ified contingency plan. <br /> An emergency coordinator Ind modified contingency plan information is lacking. There must be at least one <br /> emergency coordinator on ite or on call to coordinate emergency response measures, and the following information <br /> must be posted by a phone: the name and phone number of the emergency coordinator; location of fire extinguishers, <br /> spill control equipment, and if present, fire alarm; and the phone number of the fire department, unless the facility has <br /> a direct alarm. Immediately appoint an emergency coordinator and post the required information by a phone. A form <br /> is provided that can be usec for this purpose. <br /> This is a minor violation. <br /> Received by Inspect r: Phone: Date: <br /> (initial): ;Z'-. d►" MUNI PPA NAIDU, Lead Senior REHS (209)468-3439 03/11/2015 <br /> Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.