My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2200 - Hazardous Waste Program
>
PR0513989
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/19/2019 12:04:33 PM
Creation date
12/19/2019 12:03:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0513989
PE
2220
FACILITY_ID
FA0009699
FACILITY_NAME
PG&E: West Lane Substation
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
02
SITE_LOCATION
4040 West Ln
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Jo<-^-tin County Environmental Health ^epartment <br /> Ur d Hazardous Waste Generator I gram <br /> Site Name YCa � Address 131kq`�o \A <br /> VIOLATIONS <br /> TANKS <br /> Existing systems (installed before 7/14/86) <br /> 61_66265.191(a) (CCR) Failed to determine if tank is leaking or unfit. <br /> 62—66265.191(b) (CCR)Assessment not sufficient. <br /> 63_66265.191(d) (CCR) If found leaking or unfit,failed to comply with 66265.196. <br /> New systems (installed after 7/14/86) <br /> 64 66265.192 (CCR) Failed to retain on-site required certification. <br /> 65_66265.193 (CCR) Failed to provide secondary containment. <br /> 66_66265.194(a) (CCR) Placed hazardous waste or reagents in tank system which caused the tank, containment <br /> system or ancillary equipment to leak, corrode, rupture, or fail. <br /> 67 66265.194(b) (CCR) Failed to use controls and practices to prevent spillage and overflows from tank system. <br /> 68_66265.194(b)(3)(CCR) Failed to prevent overtopping. <br /> 69_66265.195(a)(CCR) Failed to conduct daily inspections. <br /> 70_66265.195(b)(CCR) Failed to inspect cathodic protection system. <br /> 71_66265.196 (CCR) Failed to immediately remove tank system or secondary containment system that had leaked or <br /> spilled. <br /> 72_66265.197 (CCR)During tank closure,failed to remove or decontaminated all waste residues, contaminated tank <br /> system, soils, and manage them as hazardous waste. <br /> 73_66265.198(a)and/or(b)(CCR) Failed to manage ignitable or reactive waste properly. <br /> 74_66265.199(a)and/or(b)(CCR) Failed to manage incompatible wastes properly. <br /> UNIVERSAL WASTE <br /> 75._66273.14 (CCR) Small Quantity Handler did not mark or label the universal waste as specified in this section. <br /> 76._66273.15(a) (CCR)Small Quantity Handler had universal waste onsite for more than one year. <br /> 77. 66273.15(c) (CCR)Small Quantity Handler was unable to demonstrate the length of time the universal waste has <br /> been accumulated from the date it became a waste or was received. <br /> 78.66273.1 (CCR) Small Quantity Handler did not inform employees who handle universal waste proper handling and <br /> emergency procedures. <br /> 79._66273.32 (CCR) Large Quantity Handler did not notify the EPA Regional Administrator to obtain an EPA ID <br /> number. <br /> 80._66273.33 (CCR) Large Quantity Handler did not manage universal waste according to this section. <br /> 81._66273.34 (CCR) Large Quantity Handler did not label universal waste according to this section. <br /> 82. 6273.35(a) (CCR) Large Quantity Handler had universal waste onsite for more than one year. <br /> 83.66273.35(b) (CCR) Large Quantity Handler was unable to demonstrate the length of time the universal waste has <br /> been accumulated from the date it became a waste or was received. <br /> 84._66273.36 (CCR) Large Quantity Handler did not inform employees who handle universal waste proper handling <br /> and emergency procedures <br /> 85._66273.39 (CCR) Large Quantity Handler did not keep records of each shipment of universal waste according to <br /> this section. <br /> 86._66273.82(b) (CCR)Cathode Ray Tube (CRT) handler that accepts more than 5 CRT devices per calendar year <br /> from any offsite source failed to notify DTSC and the CUPA according to section. <br /> 87._66273.82(c) (CCR)CRT handler that generates 5,000 kilograms or more of CRT material per calendar year failed <br /> to notify DTSC and the CUPA according to this section. <br /> OTHER <br /> 88_See attached "Continuation-Official Inspection Report"for violation(s)not listed above. <br /> SPCC <br /> 89_25270-25270.13 (HSC) Spill Prevention Control and Countermeasure Plan on site for aboveground <br /> petroleum storage tank(s). <br /> �7 Page y of 5 <br /> EHS Ini d by Date <br /> 3/23/02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.