Laserfiche WebLink
Y) ) <br /> EDB was detected in MW#I for this event <br /> CONCLUSIONS <br /> The water table elevations on this site continue to fluctuate Concentrations of TPHg have continued <br /> fluctuating in the shallow wells with the rise and fall of the groundwater elevation The groundwater <br /> gradient was to the northwest for thus event, a change from the previous event The last event had a <br /> hydraulic gradient to the west, which was a complete reversal of the historic trends If the present <br /> condition continues,this may explain the plume movement to the west under the building It also may <br /> be concluded that when the groundwater elevation drops,the gradient changes from the east to the west <br /> RECOMMENDATIONS <br /> The work plan under funding consideration by the UST Fund should address many concerns about the <br /> scope of the investigation of both 1,2-DCA and EDB Results from both the CPT work and the two new <br /> monitoring wells should give information for future recommendations It is recommended that the site <br /> continue to be monitored on a quarterly basis <br /> WORK IN PROGRESS <br /> The work in progress,is quarterly monitoring of the existing monitoring wells The soil stockpile on the <br /> westside of the site has been classified as non-detect for all analytes Preapproval for stockpile removal <br /> and the aforementioned work plan have been requested of the UST Fund <br /> Please contact Ervin Rifenburg of this office if you have any questions on these reports <br /> Respectfully submitted, <br /> Q��ssio�� <br /> Foothill Enginee �, yaflsFrk6_2 ��c�y� <br /> `"+" No 197 0 <br /> Ervin Rifenburg, E <br /> OFC <br /> Attachments Water Analysis Report, Del-Tech Report, Site Map, Water Sample Analysis Recap <br /> Concentration Contours, Soil Sample Analysis Recap, As-built of MW#9S & D <br /> cc Sheldon Heckman, Connell Motor Truck Co one copy <br /> Kama Harngfeld 2291 W March Lane Suite B100 Stockton CA 95207 one copy <br /> i <br /> 3 <br />