`.r+ <br /> SMTH SITE SAFETY PLAN <br /> ❑ Confined Space Entry !follow SMTH's Confined Space Entry Procedures) <br /> © Other - explain hazard and mitigation <br /> EXPOSURE MONITORING <br /> All sample results will be recorded in the SMTH exposure log. Log copies are filed in the job file, and <br /> in all site personnel's medical file, and maintained in the job file. All sampling instruments will be <br /> calibrated per the manufacturers instructions on a daily basis. <br /> *Note calibration gas and any unusual calibration settings in the "monitoring equipment" column. <br /> **Include monitoring for health hazards, explosion hazards, etc. <br /> Monitoring Hazard Sample Sample Action <br /> Equipment Monitored Location Frequency Level Action <br /> OVMIPID Organic Vapors 20 ppm* Level c w/112 <br /> or full face <br /> respirator <br /> OVMIPID Organic Vapors >200 ppm Evacuate <br /> Site <br /> * Benzene is not specifically monitored for with a OVM so any vapor reading at 20 ppm must require <br /> 1/2 face respirator. <br /> Identify sample locations on site map. <br /> PAG E 6 <br />