My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0081206 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
12882
>
2600 - Land Use Program
>
SR0081206 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/26/2019 2:14:29 PM
Creation date
12/26/2019 1:59:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0081206
PE
2602
FACILITY_NAME
CALIFORNIA ISLAMIC CENTER
STREET_NUMBER
12882
Direction
N
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
LODI
Zip
95242
APN
05807023
ENTERED_DATE
9/26/2019 12:00:00 AM
SITE_LOCATION
12882 N LOWER SACRAMENTO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
131
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> Test Hole#1 <br /> 3/26/2010 3.3 150 4 hr. Failed* <br /> Shallow Test <br /> Test Hole#2 <br /> 3/26/2010 14.7 27.2 4 hr. Satisfactory perc. <br /> rate <br /> Shallow Test <br /> Note: A satisfactory percolation rate for a "shallow" test is greater than 1 but less than or equal to 60 minutes per <br /> inch. A satisfactory percolation rate for a "deep"test is greater than 1 but less than or equal to 30 minutes <br /> per inch. <br /> * Only one test (shallow or deep) is required to pass for the Site to be considered adequate for a standard <br /> septic system. <br /> 1 Per San Joaquin County Environmental Health Department, a rate between 5.0 and 30.0 min/in requires an <br /> eight-foot separation between the bottom of dispersal system and ground water, or mitigation by system <br /> design or enhancement. <br /> Discussion of Percolation Test Results <br /> The soils within the proposed sewage disposal area of the Site have demonstrated a <br /> satisfactory percolation rate for the use of a standard septic system in accordance with <br /> the requirements of the San Joaquin County Environmental Health Department. <br /> Because of the percolation rate between 5.0 and 30 min/in encountered in the deep test <br /> hole, the San Joaquin County Environmental Health Department will require an eight- <br /> foot separation from the bottom of the dispersal system to ground water. Ground water <br /> is anticipated to be encountered approximately 56 to 59 feet below ground surface at <br /> the Site; consequently, no modifications to standard septic systems should be required. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines and seepage pits should follow the San <br /> Joaquin County On-Site Wastewater Treatment Systems Standards (2017) where <br /> applicable. <br /> LOGE 1939 Page 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.