My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0005344 ENG DES PLN
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WOODBRIDGE
>
4620
>
2600 - Land Use Program
>
PA-0500531
>
SU0005344 ENG DES PLN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/29/2020 5:18:25 PM
Creation date
12/27/2019 8:23:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
ENG DES PLN
RECORD_ID
SU0005344
PE
2627
FACILITY_NAME
PA-0500531
STREET_NUMBER
4620
Direction
E
STREET_NAME
WOODBRIDGE
STREET_TYPE
RD
City
ACAMPO
APN
01709002
ENTERED_DATE
8/26/2005 12:00:00 AM
SITE_LOCATION
4620 E WOODBRIDGE RD
RECEIVED_DATE
8/26/2005 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\W\WOODBRIDGE\4620\PA-0500531_PA-0300206\SU0005344\ENG DES PLN.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
230
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Magnetoflow® Model Magnetoflow Technical <br /> Mag Meter Flanged Brief <br /> GENERAL <br /> Badger's Magnetoflow line is the result of 35 years of research <br /> and field use in electromagnetic flow meters. Based on <br /> Faraday's law of induction,these meters can measure almost wF_ <br /> any liquid, slurry or paste that has a minimum of electrical <br /> conductivity. Designed, developed and manufactured under <br /> the strictest quality standards, the Magnetoflow meter ranks <br /> among the best in the market.Its sophisticated,processor based <br /> signal conversion represents the state of the art in the industry <br /> with accuracies of 0.25%or better.The wide selection of liner <br /> and electrode materials insures maximum compatibility and <br /> minimum maintenance over a long operating period. <br /> OPERATION <br /> The flow meter is basically a stainless steel tube lined with a <br /> nonconductive material. Outside the tube two DC powered <br /> electromagnetic coils are positioned diametrically opposing <br /> each other. Perpendicular to these coils, two electrodes are <br /> inserted into the flow tube. When the coils are energized, a Magnetoflow®Flanged <br /> magnetic field is created across the whole diameter of the pipe. <br /> When a conductive fluid flows through this magnetic field, a <br /> voltage is induced across the electrodes.This voltage is di- FEATURES <br /> rectly proportional to the average flow velocity of the fluid and <br /> is picked up by the two electrodes.This induced voltage is then • 0.25% accuracy independent of fluid viscosity, density <br /> amplified and processed digitally by the converter to produce a and temperature <br /> very accurate analog or digital signal.The signal can then be • Unaffected by most solids contained in fluids <br /> used to indicate flow rate, totalization or to communicate to . Pulsed DC magnetic field for zero point stability <br /> remote sensors and controllers.The main advantages of this <br /> technology are that with no parts in the flow stream,there is no • No pressure loss for low operational costs <br /> pressure loss, the accuracy is not affected by temperature, • Long life corrosion resistant liners <br /> pressure, viscosity, density or flow profile and with no moving . Calibrated in state of the art facilities <br /> parts there is practically no maintenance required. <br /> • Integral and remote signal converter availability <br /> n • Optional grounding rings or grounding electrode <br /> Coil • Measurement largely independent of flow profile <br /> DC supply • NSF listed <br /> Electrod <br /> lifer <br /> Electrodes <br /> Fo <br /> The two measuring electrodes, when looking from the end of <br /> the meter into the inside bore,are positioned at 3 o'clock and 9 <br /> o'clock. Badger Meter's Magnetoflow Mag meters have an <br /> APPLICATION "Empty Pipe Detection" feature.This is accomplished by the <br /> use of a third electrode that is positioned between 12 o'clock <br /> Because of its inherent advantages over other more conven- and 1 o'clock in the meter. At any time this electrode is not <br /> tional technologies, this meter can be used in the majority of covered by fluid,(for a minimum of a five second duration),the <br /> industrial flow applications.Whether the fluid is water or some- meter will display an Empty Pipe Detection condition,send out <br /> thing highly corrosive,very viscous,contains a moderate amount an error message if desired, and stop measuring to maintain <br /> of solids or requires special handling,this meter will be able to accuracy. When the electrode again becomes covered with <br /> accurately measure it.Today Magnetoflow meters are success- fluid,the error message will disappear and the meter will con- <br /> fully being used in most industries including food and bever- tinue measuring. <br /> age, pharmaceutical, water and wastewater, and chemical. <br /> As an option to the use of a set of grounding rings, to assure <br /> proper grounding in a given installation a grounding electrode <br /> (4th electrode)can be installed in the meter when initially fabri- <br /> cated.The position of this electrode is about 5 o'clock. <br /> BadgerMeter, Inc. ITB-106-02 <br /> ® Appendix-iii-15 of 40 08/17/07 aoe <br />
The URL can be used to link to this page
Your browser does not support the video tag.