Laserfiche WebLink
.rte V INTERNATIONAL.TECHNOLOGY CORPORATION <br /> Ms. Mary Meays <br /> 2 January 25, 1995 <br /> 3. _ (paragraph 1; page 2): "Please b aware that for verification sampling of the <br /> excavation, soil samples should be collected for analysis every 20 feet and therefore, it <br /> may be necessary to collect more than five soil samples as proposed by the plan." <br /> RRA 3: The rate of verification sampling has been estimated by IT in our: "Interim <br /> Corrective Action Plan," however, if the size of the actual excavation and/or field <br /> conditions warrant the collection of additional samples, the appropriate samples will be <br /> collected. <br /> 4; to 'aph 2; page 2): "It is unclear how the annular space will be filled <br /> with an approved bentonite grout mixture. Please submit a permit application completed <br /> by a C-57 California contractor, $99 permit fee, and a description of how the vapor well <br /> will be sealed." <br /> Response 4: The vapor observation point will consist of a slotted PVC screen, laid <br /> horizontally across the base of the excavation on a bed of gravel. The horizontal well <br /> will be attached to a vertical stand pipe, extended to six inches below grade. The <br /> excavation will be backfilled around the vapor observation standpipe. The well head <br /> (approximately one foot of standpipe) will be contained in a traffic rated well box. The <br /> well box will be cemented into place during resurfacing of the excavated area. The <br /> annular space surrounding the well will not.be filled with bentonite but will be sealed <br /> only with the envelope of geotextile fabric, the overlying pavement surface and cement at <br /> the base of the well box. <br /> A permit application, fees, and a description of the well installation procedures and <br /> specifications, will be submitted to the PHS/EHD prior to initiation of field activities. <br /> 5. Comments 5 (paragraph 3; page 2): '"The plan indicated that the vapor well would be <br /> used to monitor volatile petroleum hydrocarbons. As PHS/EHD indicated, the major <br /> contaminant does-not readily emit volatile constituents which may be detected" <br /> Response 5: The vapor observation point will be utilized to monitor volatile petroleum <br /> hydrocarbons (if any) which remain in native soil following overexcavation activities. <br /> This monitoring point will be located so as to be incorporated into a future soil <br /> remediation system as conditions warrant. It is possible that no detectable volatile <br /> petroleum hydrocarbons will be encountered. <br />