My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3505
>
2900 - Site Mitigation Program
>
PR0009275
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2020 2:58:37 PM
Creation date
1/7/2020 2:10:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0009275
PE
2960
FACILITY_ID
FA0004014
FACILITY_NAME
VALERO ENEREGY CORP/NUSTAR ENERGY
STREET_NUMBER
3505
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95203
APN
16203003
CURRENT_STATUS
01
SITE_LOCATION
3505 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
317
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Califoirnia Reftonal Water Quality Control Board <br /> Central Valley Region - <br /> f <br /> Steven T.Butler, Chair <br /> Winston H.Hickox Gra Davis <br /> Seeretaryfor Y <br /> Sacramento M�in.,Q�F'eF O ': 55 Governor <br /> Environmental l Internet Address: http://www.��c�r.6d.go 'rwq b`51 <br /> Protection 3443 Routier Road,Suite A,Sacramento,California 95827-3003 <br /> Phone(916)255-3000•FAX(916)255-3015 <br /> 15 August 2000 <br /> Mr. Scott Hooton Mr. Larry Silva Mr. Kyle Mullins <br /> BP Exploration and Oil Inc. Tosco Refining Company ST Services <br /> 295 SW 41" Street, Bldg. 13, Ste. N P.O. Box 2628 17304 Preston Road <br /> Renton, WA 98055-4931 9645 Santa Fe Springs Road Suite 1000 <br /> Santa Fe Springs, CA 90670 Dallas, Texas 75252 <br /> WORK PLAN APPROVAL, FORMER BP TERMINAL # 10013, 3505 NAVY DRIVE, <br /> STOCKTON, SAN JOAQUIN COUNTY <br /> I have reviewed Cambria's 21 July 2000 Subsurface Investigation Work Plan for the former BP Oil Bulk <br /> Terminal No. 10013 at 3505 Navy Drive in Stockton. The work plan proposes to determine the source of <br /> methyl tertiary butyl ether(MTBE) and define the lateral and vertical extent of the offsite MTBE plume. <br /> Specifically, the work plan recommends to do the following: (1) Drill eight to 12 borings near the <br /> loading rack and along the vapor recovery line and parallel to the western property boundary west of <br /> monitoring well (MW) 8; (2) Collect continuous soil samples to five feet below the water table and <br /> groundwater samples from each boring; (3) Analyze the samples for total petroleum hydrocarbons (TPH) <br /> as gasoline, benzene, toluene, ethylbenzene and xylenes (collectively BTEX), and MTBE; (4) Perform <br /> slug tests at selected MWs to estimate hydraulic conductivity; and (5) Submit an investigation report. <br /> My comments on the work plan are presented below. <br /> 1. In addition TPHg, BTEX, and MTBE, the testing program also needs to include TPH as diesel. <br /> 2. The work plan proposes to define the lateral and vertical extent of MTBE pollution, but the proposed <br /> groundwater sampling would define the lateral extent only. The work plan also should provide <br /> provisions to define the vertical extent of pollution. <br /> 3. The investigation report should be prepared in general accordance with Attachment 1, Iters To Be <br /> Included In A Site Assessment Report. <br /> The work plan is hereby approved provided that it incorporates Items 1 and 2 above. By <br /> 29 August 2000, please submit a schedule to: (1) Implement the work plan and (2) Submit the <br /> investigation report. <br /> California Environmental Protection ,A ency <br /> �� Recycled Paper <br />
The URL can be used to link to this page
Your browser does not support the video tag.