My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1987
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3505
>
2300 - Underground Storage Tank Program
>
PR0231848
>
INSTALL_1987
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2020 12:06:48 PM
Creation date
1/9/2020 11:48:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1987
RECORD_ID
PR0231848
PE
2361
FACILITY_ID
FA0002052
FACILITY_NAME
NuStar Terminals Operations Partnership L.P.
STREET_NUMBER
3505
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
16203004
CURRENT_STATUS
01
SITE_LOCATION
3505 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SMETIM <br /> INSTALLING UL LISTED RED THREAD II <br /> PRODUCT PIPE LINES (continued) �I <br /> SUCTION PUMP <br /> IMSTALLAnoNs <br /> PUMP MLAf@ . <br /> VIE <br /> Dave <br /> TD THREAD <br /> II R.a1SlE +. Min. Min.Amount of Sand <br /> .ADAPTER CONNECTION _ Burial or Pea Gravel above <br /> ix Size Surface Condition Depth the top of the pipe <br /> i <br /> SUCTION PUMP PUMP 2" Unpaved 17" 12" <br /> MIALLATIONS DIST Paved,min.4"asphalt 12" 8" <br /> Paved,min.4"concrete 9" 5" <br /> 3" Unpaved 20" 14" <br /> Paved,min.4"asphalt 13" 9" <br /> Paved,min.4"concrete 11" 7" <br /> OALVANrZED TO <br /> qED THREAD 11 FLEXIBLE <br /> VALVE 4" Unpaved 20" 14" <br /> TNREA Eo AOAPTEq CONNE�IDN _ Paved.min.4"asphalt 14" 10" <br /> GALVANIZED Paved,min.4"concrete 11" 7" <br /> SWING <br /> ASSEMBLY Cal <br /> TYPICAL ISLAND PIPING IJ <br /> PLUMBING—To make installation easier and to Minimum burial depths shown in the above burial table are <br /> conserve adhesive,all measuring,cutting,and tapering acceptable if,and only if,the ditch width is 2.5 feet or less; (v <br /> should be done first.Then proceed with the bonding the paved surfaces extend at least 2 feet on either side of <br /> operation.To make sure measurements are right, the ditch; the fill material is clean sand or 1/e"to 1/2" pea <br /> assemble the entire piping system "dry'(without adhesive) gravel and 6" of the fill material is placed under the pipe as <br /> before bonding.Where accuracy is important,"dry' bedding material. <br /> assembly is a must. For close tolerance piping refer to Remaining backfill above Sand or Pea Gravel amounts as <br /> Smith Fiberglass Installation Manual No.9474, shown in the last column of the burial table can be native <br /> FLEXIBLE HOSE CONNECTIONS— Flexible hose soil if desired. <br /> connections can be installed in product and vent lines at If burial conditions other than those discussed above exist, <br /> the point where they leave the tank.On suction pump contact Smith Fiberglass Products. <br /> installation they can be put in just before the pump riser. <br /> Use of flexible connections can prevent breaking of lines REPAIRING—On rare occasions it may be necessary to <br /> or fittings where settlement might cause tank movement,or repair a damaged section of RED THREAD II pipe.Where <br /> where expansion and contraction might cause movement damage is in the form of a puncture,the pipe can be <br /> of the pipe. repaired using a patch made from the pipe itself. If a <br /> The drawings above of typical island piping indicate how considerable length of pipe is involved, it is best to replace <br /> connections can be made using standard RED THREAD it with a new section of pipe.Complete information for <br /> II adapters. making repairs is included in the Smith Fiberglass UL <br /> Installation Instructions Manual No. 1055. <br /> BURIAL— Minimum acceptable burial depths are given <br /> in this section. In some cases greater depths may be For industry reference, see API Publication 1615 <br /> required by the authority having jurisdiction or by local "Installation of Underground Petroleum Storage Systems", <br /> codes. and PEIIPP100-86 "Recommended Practices for <br /> The maximum allowable burial depth is 24 feet for burial in Installation of Underground Liquid Storage Systems" <br /> moderately compacted soils which do not contain clay <br /> and where the soil modulus is at least 1000 psi. <br /> I <br /> (3)RED THREAD ii pipe is inherently flexible.API Publication 1615 states: <br /> "Fiberglass piping,which is inherently flexible,does not require swing <br /> joints,if at least 4 feet of straight run is provided between any directional <br /> change exceeding 30 " <br />