Table 2 <br /> Fuel Oxygenates Analytical Data <br /> ARCO Service Station No.5450 <br /> 1617 West Fremont Street,Stockton,Califomia <br /> Well Date TBA MtBE DIPS EtBE TAME 1,2-DCA EDB Ethanol <br /> Number Sampled Um&) (m L) WL) g!L) (N L) g1L) W ) <br /> MW-2 9/11/2002 <20 62 <0.5 <0.5 <0.5 <0.5 <0.5 <40 <br /> 11/27/2002 <20 43 <0.5 <0.5 <0.5 <0.5 <0.5 -- <br /> 3/14/2003 <20 26 <0.5 <0.5 <0.5 <0.5 <0.5 <br /> 4/24/2003 <20 30 <1.0 <1.0 <1.0 <0.5 <0.5 <100 <br /> 8/14/2003 <20 18 <1.0 <1.0 <1.0 <0.5 <0.5 <100 <br /> MW-3 9/11/2002 <20 0.77 <0.5 <0.5 <0.5 <0.5 <0.5 <40 <br /> 11/27/2002 <20 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 -- <br /> 3/14/2003 <20 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 -- <br /> 4/24/2003 <20 <0.5 <1.0 <1.0 <1.0 <0.5 <0.5 <100 <br /> 8/14/2003 <20 <0.5 <1.0 <1.0 <1.0 <0.5 <0.5 <100 <br /> MW-4 9/11/2002 <20 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <40 <br /> 11/2712002 <20 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 -- <br /> 3/14/2003 <20 0.69 <0.5 <0.5 <0.5 <0.5 <0.5 -- <br /> 4/24/2003 <20 0.66 <1.0 <1.0 <1.0 <0.5 <0.5 <100 <br /> 8/14/2003 <20 1.5 <1.0 <1,0 <1.0 <0.5 <0.5 <100 <br /> Notes: <br /> < = below given laboratory detection limit EDB = Ethylene dibromide TAME = Tertamyl methyl ether <br /> 1,2-Dca = 1,2-Dichioroethane EtBE = Ethyl tert-butyl ether TBA = Tert-butyl alcohol <br /> DIPE = Di-isopropyl ether MtBE = Methyl tert-butyl ether pg/L = micrograms per liter <br /> Data Qualifier Definitions: <br /> U The analyte was analyzed for, but was not detected above the sample reporting limit. <br /> J The analyte was positively identified;the associated numerical value is the approximate concentration of the analyte in the sample. <br /> N The analysis indicates the presence of an analyte for which there is presumptive evidence to make a"tentative identification." <br /> NJ The analysis indicates the presence of an analyte that has been"tentatively identified"and the associated numerical value represents its approximate <br /> concentration. <br /> UJ The analyte was not detected above the reported sample reporting limit. However,the reported reporting limit is approximate and may or may not <br /> represent the actual limit of quantitation necessary to accurately and precisely measure the analyte in the sample. <br /> R The sample results are rejected due to serious deficiencies in the ability to analyze the sample (i.e.,the presence or absence of the analyte cannot be <br /> verified)or the analyte identification has been rejected(i.e.,the presence of the analyte cannot be verified). <br /> ND Not detected above reported detection limit <br /> KAVIprocessQ5 SP ARC010545054uarferIN QTR 0315450 GwMR 3003 <br />