Laserfiche WebLink
1 INTRODUCTION <br /> This report presents the results of EMCON Associates' (EMCON's) pre- <br /> liminary site assessment of gasoline-impacted soil and ground water at the <br /> Nor-Cal Beverage Company, Inc. (Nor-Cal Beverage) facility located at <br /> - 1800 East Fremont Street, Stockton, California (see Figure 1). This <br /> assessment was conducted in May 1991. <br /> The purpose of this environmental assessment was to characterize the <br /> vertical extent of soil contamination and the magnitude of ground-water <br /> impact, it any, due to the release of petroleum hydrocarbons associated <br /> �. with three underground gasoline storage tanks which were located at the <br /> site and removed in January 1991. This characterization was co,iducted <br /> - consistent with the May 1991 EMCON document entitled Work Plan for <br /> M Environmental Services, 1800 East Fremont Street, Stockton, California, <br /> as approved by Nor-Cal Beverage and the San Joaquin County Depart- <br /> ment of Public Health Services. This report presents background informa- <br /> tion on the site, the site geology, field activities, sampling and analysis <br /> procedures, analytical results, and conclusions and recommendations. <br /> pig\g05\g050101d 1 Rev, 0 July 2, 1991 <br /> Emcoff Associates <br />