COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
12 (STATE ROUTE 12)
>
5400
>
2800 - Aboveground Petroleum Storage Program
>
PR0545140
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 3:46:02 PM
Creation date
1/10/2020 9:28:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0545140
PE
2832
FACILITY_ID
FA0025200
FACILITY_NAME
CECCHINI TRUCKING CO INC, CTC CFC
STREET_NUMBER
5400
Direction
W
STREET_NAME
STATE ROUTE 12
City
LODI
Zip
95242
APN
05516072
CURRENT_STATUS
01
SITE_LOCATION
5400 W HWY 12
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Item <br />Task <br />Status <br />Comments <br />5.5 Strainer <br />b. Access strainer <br />❑Yes ❑No* ❑N/A <br />basket and check cap <br />and gasket seal as <br />well as bolts. <br />5.6 Filter <br />a. Check that the filter <br />❑Yes ❑ No* ❑ N/A <br />is in good condition <br />and is within the <br />manufacturer's <br />expected service life. <br />Replace, if necessary. <br />b. Check for leaks and <br />❑Yes ❑ No* ❑ N/A <br />decreased fuel flow <br />5.7 Flame <br />Follow manufacturer's <br />❑Yes* ❑ No ❑N/A <br />arrestors <br />instructions. Check for <br />corrosion and <br />blockage of air <br />passages. <br />5.8 Leak detector <br />Test according to <br />❑Yes ❑No* ❑N/A <br />for <br />manufacturer's <br />submersible <br />instructions and <br />pump <br />authority having <br />systems <br />jurisdiction (AHJ). <br />Verify leak detectors <br />are suited and <br />properly installed for <br />aboveground use. <br />5.9 Liquid level <br />a. Has equipment <br />❑Yes ❑No* ❑N/A <br />equipment <br />been tested to ensure <br />proper operation? <br />b. Does equipment <br />❑Yes ❑No* ❑N/A <br />operate as required? <br />c. Follow <br />❑Yes []No* ❑ N/A <br />manufacturer's <br />instructions <br />5.10 Overfill <br />a. Follow <br />❑Yes ❑No* ❑N/A <br />equipment <br />manufacturer's <br />instructions and <br />regulatory <br />requirements for <br />inspection and <br />functionality <br />verification. <br />b. Confirm device is <br />❑Yes ❑No* ❑N/A <br />suited for above <br />ground use by the <br />manufacturer <br />AST INSPECTION STANDARD 11 SEPTEMBER 2011 <br />COPYRIGHT© 2011 Steel Tank Institute <br />