My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3505
>
2300 - Underground Storage Tank Program
>
PR0231848
>
COMPLIANCE INFO_2006 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:33:46 PM
Creation date
1/10/2020 1:36:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2018
RECORD_ID
PR0231848
PE
2361
FACILITY_ID
FA0002052
FACILITY_NAME
NuStar Terminals Operations Partnership L.P.
STREET_NUMBER
3505
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
16203004
CURRENT_STATUS
01
SITE_LOCATION
3505 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
307
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer ❑✓ Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑✓ Vacuum ❑Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used:Test plugs,venturi pump and guages Equipment Resolution: 0.5%of Span inHg <br /> Tank#Contact WAter Tank# Tank# Tank# <br /> is Tank Exempt From Testing?' ❑Yes ❑✓ No []Yes No ❑Yes ❑No ❑Yes [-]No <br /> Tank Capacity: 10k <br /> Tank Material: Fiberglass <br /> Tank Manufacturer: Unknown <br /> Product Stored: Contact Water <br /> Wait time between applying <br /> pressure/vacuum/water and 10 Minutes 10 Minutes 10 Minutes 10 Minutes <br /> -starting test: <br /> Test Start Time. 10:30AM <br /> Initial Reading(Rl): 7 inHg inHg inHg inHg <br /> Test End Time: 11:30AM <br /> Final Reading(RF): 7 inHg inHg inHg inHg <br /> Test Duration: 1 Hour <br /> Change in Reading(RF-R,): 0 <br /> Pass/Fail Threshold or Criteria: 0 0 0 0 <br /> Test Result: ❑✓ Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail <br /> Was sensor removed for testing? []Yes ❑✓ No [_-INA ❑Yes [-]No ❑NA []Yes[]No []NA ❑Yes ❑No [INA <br /> Was sensor properly replaced and ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ r ❑ <br /> verified functional after testing? Yes No NA Yes No NA ❑Yes No NA Ycs 1\o NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 'Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23,Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.