My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3505
>
2300 - Underground Storage Tank Program
>
PR0231848
>
COMPLIANCE INFO_2006 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:33:46 PM
Creation date
1/10/2020 1:36:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2018
RECORD_ID
PR0231848
PE
2361
FACILITY_ID
FA0002052
FACILITY_NAME
NuStar Terminals Operations Partnership L.P.
STREET_NUMBER
3505
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
16203004
CURRENT_STATUS
01
SITE_LOCATION
3505 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
307
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t - ND <br /> J-J `+ 07 26118 <br /> 6. PIPING SUM"TESTING _ EWARONMENTA NT <br /> Test Method Developed By: ❑Sump Manufacturer Q Industry Standard ❑Profess1drEA rt r <br /> _ ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum ❑Hydrostatic <br /> []Other(Spec) <br /> Test Equipment Used: Incon Sump Tester v Equipment Resolution: +I_0.002 Inches <br /> =_.a _Sump# 1 Sump# — :I Sump# Sump# <br /> Sump Diameter: 42" <br /> Sump Depth: 48" _ <br /> Sump Material: Fiberglass <br /> Height from Tank Top to Top of 12" <br /> Highest Piping Penetration: <br /> I{eight from Tank Top to Lowest 191, <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Good <br /> Portion of Sump Tested' 2"Above Piping <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑No ❑✓NA []Yes ❑No ❑NA ❑Yes❑ No [:]NA ❑Yes ao ❑NA ' <br /> product and water)?* - <br /> Turbine shutdown response time N/A NIA N/A N,'A <br /> Is system programmed for fail-safe ❑Yes ❑No ❑✓NA ❑Yes [jvo []NA ❑Yes[:] No El NA ❑Yes ❑-4o DNA <br /> shutdown?` <br /> Was sail-safe verified to be ❑Yes ❑No ONA ❑Yes ❑No [:INA ❑Yes ❑No ❑NA ❑Y'es ❑No ❑NA <br /> operational?'_._.__.___ <br /> Wait time between applying <br /> pressure/vacuum' ater and starting 30 Minutes 30 Minutes 30 Minutes 30 Minutes <br /> test: <br /> `i est Start Time: 11:47AM <br /> Initial Reading(R,): 5.5824 Inches Inches I Inches _ inches <br /> Test End Time: 12:02PM <br /> Final Reading(Kr): T �— 5.5821 Inches Inches Inches Inches <br /> Test.Duration: 15 Minutes T_ _ <br /> Change in Reading(R,-R,): 0.0003 <br /> Pass/--ad Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: ❑Pass ❑Fail [I Pass []Fail []Pan all] ❑Paws ❑Fail <br /> Was sensor removed for testing? [2]Yes ONO []NA ❑Yes []No ❑NA ❑Yes ONO []NA []Yes ❑No []NA <br /> Was sensor properly replaced and OYes ❑No DNA ❑Yes❑No ❑NA ❑Yes ❑No ❑NA ❑Yes❑No ❑NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing;and recommended follow-up for failed tests) <br /> T-1 increase. Retest. Pass. <br />
The URL can be used to link to this page
Your browser does not support the video tag.