Laserfiche WebLink
PROVIDE A BRIEF NARRATIVE DESCRIPTION OF THE PROPOSED ACTIVITIES: <br /> Advance 5 soil borings (LPB1 through LPB5) to between 30 and 55 feet <br /> bgs with a Geoprobe 6600 direct push drilling rig to investigate potential <br /> contamination near the inactive clarifier. Collect groundwater sample from <br /> boring LPB1 to determine if groundwater has been impacted. Analyze soil <br /> and groundwater samples based upon field parameters (odor, <br /> discoloration, FID) for presence of petroleum hydrocarbons (TPHg, BTEX, <br /> VOCs, Oxys). <br /> SECTION III. SPECIFIC SITE INFORMATION <br /> SPECIFIC TANK SYSTEM INFORMATION: Previously had USTs on site, but removed <br /> in 1992 and site closed. Currently investigating inactive equipment wash area and <br /> clarifier. <br /> Age/Size/Capacity of Tanks and Piping: N/A <br /> Contents of Tank: N/A <br /> Other(specify): <br /> TYPE OF SITE <br /> CHECK ALL APPROPRIATE: <br /> ® Active ❑ TSDF <br /> ❑ Inactive ❑ R&D Facility <br /> ❑ Industrial Facility ❑ Military Base <br /> ❑ Gas Station ® Other (Equip. Rental) <br /> RELEASE HISTORY <br /> ❑ No evidence of leaks or soil contamination <br /> ® Suspected or known leaks and soil contamination <br /> ❑ Known ground water contamination <br />