My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS_FILE 2
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1817
>
2900 - Site Mitigation Program
>
PR0540859
>
FIELD DOCUMENTS_FILE 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2020 2:41:36 PM
Creation date
1/15/2020 2:35:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
FileName_PostFix
FILE 2
RECORD_ID
PR0540859
PE
2960
FACILITY_ID
FA0023361
FACILITY_NAME
PLAY N PARK (FORMER BARNES TRUCKING)
STREET_NUMBER
1817
Direction
S
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
CURRENT_STATUS
01
SITE_LOCATION
1817 S FRESNO AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BARNES TRUCKING + Page 1 of 2 <br /> LTCP Checklist A © GEOTRACKERHOMEIMANAGEPROJECTSIBEEORTSI � I LOGOUT <br /> BARNES TRUCKING (T0607700585) - MAP THIS SITE OPEN-REUEDIATION <br /> 1817 FRESNO AVE S CLEANUP OVERSIGHT AGENCIES <br /> STOCKTON , CA 95206 ACTIVITIES REPORT SANJOAOUIN COUNTYLOP (LEAD) - CASE M:2506 <br /> SAN JOAQUIN COUNTY PUBLIC WEBPAGE CASEWORKER: ANGELICA SANDOV - SUPERWSOIT ADRIENNEELLSAESSER <br /> VIEWPRINTABLE CASE SUM OR THISSITE CENTRAL VALLEY RWOCB (REGION 5S)A CASE 0. 390750 <br /> CASEWORKER:JAMES BARTON - SUPERVISOR: CORI CONDON <br /> CUF Claim M: 11 act, 7122 CUP Priority Assigned: B CUE Amount Paid: $1,150801 <br /> THIS PROJECT WAS LAST MODIFIED BY NOEL HENDERSON ON WSS!G142:63:26 PM - HISTORY <br /> THIS SITE HAS UNAPPROVED SUBMITTALS. DUCK HERE TO OPEN ANEW WINDOW WITH THE SUBMITTAL APPROVAL PAGE FOR THIS SITE. <br /> CLOSURE POLICY THIS VERSION IS FINAL AS OF 51812014 CHECKLISTINITIATEO ONWWO13 CLOSUREPOUCY HISTORr <br /> General Criteria - The site satisfies the po0cygeneral criteria - cLEAR sEcTfoN ANSWER NO <br /> a. Is the unauthorized release located within the service area of a public waters stem? <br /> Name of Water System : CALWATER r VES r' NO <br /> b. The unauthorized release consists only of petroleumiLl. r YES r' NO <br /> c. The unauthorized (°primary°) release from the UST system has been stopped. YES C NO <br /> d. Free product has been removed to the maximum extent practicableiinnfool. r FP Not Encountered r' YES r NO <br /> e. A Conceptual site model that assesses the nature, extent, and mobility of the release has been developed Iinfol. <br /> Description (Check all that Apply): <br /> r GW Not Evaluated <br /> I Groundwater Assessment Incomplete - Areal Extent of Contamination Not Defined! <br /> F Groundwater Assessment Incomplete - Depth of Contamination Not Defined <br /> F Hydrogeology Not Adequately Defined C VES r NO <br /> F Potential Receptors Not Identified <br /> I Soil Assessment Incomplete - Areal Extent Not Defined <br /> F Soil Assessment Incomplete - Depth Unknown <br /> F Soil Vapor Not Evaluated <br /> r Other - <br /> f. Secondary Source has been removed to the extent practicable gafc . <br /> I diment to Removing Secondary Source (Check all that Apply): <br /> F Remediation Has Not Been Attempted <br /> r Remediation Was Designed Incorrectly C YES C NO <br /> F Remediation Was Shut Off Prematurely <br /> F Poor Remediation O&M <br /> F Other - Need for additional remedialion undereval, <br /> g. Soil of groundwater has been tested for MTBE and results reported in accordance with Health and Salary Code Section f Not Required �' YES r' NO <br /> 25296.15, quit <br /> h. Does a nuisance exist, as defined by Water Cade section 13050. r YES r NO <br /> 11. Media-Specific Criteria: Groundwater - The contaminantplume that exceeds waterquality objectives is stable ordecreasing in areal extent, and NO <br /> meets all Of the additional characteristics of One Of the five classes Of Sites listed below, - CLEAR SECTION ANSMRS <br /> EXEMPTION - Soil Only Case (Release has not Affected Groundwater -L) r YES r NO <br /> Does the site meet any of the Groundwater specific criteria scenarios? C YES r NO <br /> ADDITIONAL QUESTIONS - Please indicate only those conditions that do not meet the policy criteria: <br /> Plume Length (That Exceeds Water Quality Objectives) : <br /> r z 100 Feet and < 250 Feet r z 250 Feet and < 1 ,000 Feet r z 1 ,000 Feet r Unknown <br /> Plume is Stable or Decreasing in AREAL Extent : <br /> C No C' Unknown <br /> Free Product in Groundwater : <br /> r' Yes r No C Unknown <br /> Free Product Has Been Removed to the Maximum Extent Practicable : <br /> r' No r' Unknown <br /> For sites with free product, the Plume Has Been Stable or Decreasing for 5-Years (info) : <br /> C No C' Unknown <br /> For sites with free product, owner Willing to Accept a Land Use Restriction (if required) : <br /> r No r Unknown <br /> Free Product Extends Offsite : <br /> C Yes C Unknown <br /> Benzene Concentration <br /> r z 11000 pgII and < 3,000 F911 r z 3,000 pgll r Unknown <br /> MTBE Concentration : <br /> C z 1 ,000 pgll r Unknown <br /> Nearest Supply Welt (From Plume Boundary) <br /> C s 25G Feet r' > 250 Feet and < 1 ,000 Feet C Unknown <br /> Nearest Surface Water Body (From Plume Boundary) : <br /> https ://geotracker.waterboards .ca.gov/regulators/screens/closure_policy.asp?global_id=T06. - . 5/8/2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.