I
<br /> 0 1
<br /> CT214-03 3 36
<br /> a Larry's Auto
<br /> or : � 0303-136-1 0303-136-2 0303-136-3 Method Units Detection
<br />' YP� IK MW4 VW2B VW3 Lirtut
<br /> 4,2-Dibrom6ethane(EDB)--- ND<0 5✓ ND<0 5 .- ND<0 5 EPA 826013 ug/L 0 5�'
<br />' 1,3-Dichloropropane - ND<I ND<I ND<I,- EPA 8260B ug/L 1—
<br /> Dibromochioromethme y ND<I, ND<1 ND,<l-?' ESA 8260B„,'t` ug/L 1 A,- ,
<br /> 2-Hexanone ND<10 ND<10 - ND<10-! EPA 8260B ug/L 10
<br /> 'Tetrachlaibethene %' ND<1 ND<l��P- ND<1 .EPA$2608 ug/L
<br />' Chlorobenzene ✓ ND<l / ND<l ND<1 f EPA 8260E ug/L 1
<br /> 1,1,1,2-Tetrachloroethane - NI?k1 ND<I, ND<lEPA 826013', ug/L
<br /> Ethylbenzene 4400/ 4800 r 5000 EPA 8260B ug/L 0 5--
<br /> m.p-Xylene-.�- 18000 170011,°- 17000 _ EPA 82608 - ug/L 0 6
<br /> Bromoform--- ND<I ND<l— ND<1 i EPA 8260B ug(L I�
<br /> Styrene ND<1 _ ND<l - ° 'ND<l - ' EPA,8260BP',° - ug/L: 1 1 -'`-
<br /> o-Xylene✓ 7500 7000 8100 EPA 8260E ug/L 0 6---
<br /> 1,1,2,2-Tetrachloroethane, ND<l--," ND<I ' ND<1 , ` EPN8260B' ' ug/L, 31—
<br />' 1,2,3-Tnchloropropane ND<l ND<l ND<1 �J EPA 8260B ug/L 1--
<br /> Impropylpenzene�' _ 76v 82f1 98.E EPA 8260B r c, ug/L 1<
<br /> Bromobenzene_/ ND<Ir1/ ND<1-/ ND<1/ EPA 8260B ug/L 1�-
<br />' 2;Chlorotoluene ND<I-f" ND<I— _ ND<l EPA 8260E E ug(L I--
<br /> n-Propylbenzene 240—' 170 250— EPA 8260B ug(L
<br /> 4-Chlorotoluene w. ND<l--- ND<1 NDcI EPA 8260E ug/L I `
<br /> 1,3,5-Tnmethylbenzene ✓ 1500 620 1100--� EPA 8260E ug/L 1.r
<br />' rt-Butylbenzene Z/ NEkl „r ND<1 i ND<l r EPA,8260B ug(L r I
<br /> �2,4-Tnmethylbenzene---' 38001 3500 f 3000 / EPA 8260E ug(L 1
<br /> sec-Butylbe,nzene _ND<1 ND<1 =- ND<I f EPA 8260B ug/L
<br /> 1,3-1)ichlorobenzene ND<1 i ND<I ND<1/ EPA 8260B ug/L I w
<br /> 1,4-Dichlorobenzene NDrI, ND<I ND<I EPAt826013, ug/L, 1 r
<br /> p-Isopropyl toluene 80 -1- 20 i 10 . EPA 8260B ug/L 1
<br /> 1,2-Dichlorobenzene`,,�' ND<1 `- ND<1— ND<I—` EPA 826UB,' ug/L 1✓
<br /> n-Butylbenzene ND<I' NDQ ND<1 EPA 8260B ug(L 1
<br /> 1,2 Dibromo-3-Chloropropane ;ND�cl ND<1+,� s ND<l . EPA 8260B,. _ ug/L 1 /
<br /> 1,2,4-Tnchlorobenzene— ND<I— ND<1 ND<1-- EPA 8260B ug/L 1—
<br /> ,Naphthalene-,-' , 2200 670 950 -" - EPA 8260B ug/L 11
<br /> 1,2,3-Tnchlorobenzene ND<1 - ND<1 ND<I / EPA 8260B ug/L 1
<br /> Hexachlorobutadiene ND<I,, ND<1 'ND<1 EPA 8260B, - Ug/L 11
<br /> TPH-Gasoline ,110000!" 180000 .�^' - Y 1800001,, EPA 8015M ug/L 50
<br /> TPH-Diesel I_ 80 1'` m �; EPA 8015M 4 rn�)L o05 y
<br /> 0 n
<br /> tx1 r j a
<br /> ND=Not Detected at the indicated Detection Linut
<br />' SURROGATE SPIKE %a SURROGATE RECOVERY Control Limit
<br /> Dibromofluoromethane 84 93 87 70-130
<br /> 1,2 Dichloramsthaned4 92 101 90 70-130
<br /> Toluene-I8 102 97 95 70-130
<br /> -omofluorobenzene 93 g'" 99 94 70-130
<br /> 2
<br />
|