Laserfiche WebLink
RECEIVED JAN 15 2020 <br /> Environmental Health Department <br /> U N _/ . .AIA, <br /> Underground- Storage Tank Program Inspection Report <br /> Facility Name: Facility Address : Date : <br /> CHEVRON STATION d#210997° 1442 Colony Dr, RIPON January 15, 2020 <br /> UST System Observations <br /> 313 HSC 25290. 11 25290.2, Failure to construct, operate, and maintain primary containment as product-tight o V a R o COS <br /> 25291 <br /> 314 HSC 25290. 1 , 25290. 2, Failed to have secondary containment or secondary containment not tight o V o R o COS <br /> 25291 <br /> 315 HSC 25291 (e) Water in secondary containment not removed, analyzed, and property disposed of (pre-Jul 2003) ❑ V ❑ R o COS <br /> 316 HSC 25290. 1 (c3), Secondary containment not constructed to prevent water intrusion (after Jul 2003) ❑ V ❑ R o COS <br /> 25200. 2(c3) <br /> 317 CCR 2636, 2643 (c)( 1 ), Line leak detector (LLD) not installed ❑ V o R ❑ COS <br /> 2666(f) <br /> 316 CCR 2666(c), 2643(c) Leak detector failed to detect a 3 .0 gallons per hour leak at 10 pounds per square inch o V o R o COS <br /> (1 ) <br /> L320 <br /> CCR 2635, 2637. 1 , No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested o V o R o COS <br /> 2665, 2712 <br /> CCR 2635, 2837. 2, Failure to comply with the installation, inspection , or record keeping of the overfill prevention o V ❑ R o COS <br /> 2665, 2712 <br /> CCR 2635(c)( 1 ) Overfill prevention was overridden o V c R o COS <br /> 322 NSC 25281 .6(a) Unburied below grade emergency generator system failed to meet exemption status o V o R o COS <br /> F32 <br /> NSC 25283 .5(a) Unburied below grade UST system failed to meet exemption status a V ❑ R ❑ COS <br /> CCR 2717 . 1 (g) Tampered with red tag o V o R o COS <br /> CCR 2717A (f) Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST ❑ V o R a COS <br /> 25292.3(c) <br /> HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V o R o COS <br /> 327 CCR 2631 . 1 , 2660(m) UST system not compatible with the substance stored o V o R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑ V o R o COS <br /> 329 HSC 25298; CCR 26701 Failed to comply with all permanent closure requirements o V ❑ R o COS <br /> 2672 <br /> 330 CCR 2636(f), 2666(c), No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm o V o R ❑ COS <br /> 2666(f) <br /> [333 <br /> CCR 2630(d), 2641 (a) Liquid does not flow into the sump in the event of a leak (Le. , failure to remove test boot). o V o R a COS <br /> CCR 2631 (b&d), Primary and/or secondary containment not constructed in accordance with the established standards o V a R ❑ COS <br /> 2666(b&e) <br /> CCR 2635, 2636(b), Failure to comply with the cathodic protection system requirements o V o R a COS <br /> 2662, 2712 <br /> 334 CCR 2666 (b)(2) Single-walled pipe not upgraded to double-walled Interstitially monitored pipe during repair ❑ V o R o COS <br /> 335 CCR 2630, 2632, 2643 , Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑ V o R o COS <br /> 2644. 1 <br /> 336 HSC 25292 .3 (c)(1 )(C) Owner/operator allowed dispensing from a UST that has a red tag affixed to the fill pipe o V ❑ R o COS <br /> Single-Waited Non -Pressurized Piping <br /> 401 CCR2636 (x)(3), Suction piping not property sloped or Incorrectly located check valve o V o R o COS <br /> 2641 (b) <br /> 402 CCR 2643(d) Failure to conduct monitoring / maintain records for single-walled conventional suction (pre-1984) o V o R o COS <br /> 403 CCR 2643 (d), 2661 (f) Failure to conduct 0. 1 gph test for single,,walled conventional suction systems (pre-Jan 1984) o V o R o COS <br /> 404 CCR 2643(e), 2661 (f) OAgph line test for single-walled gravity piping not performed biennialy or post repair (pre-1984) ❑ V o R o COS <br /> FA0013918 PR0518458 SC001 01 /15/2020 <br /> i <br /> EHD 23,01 Rev. 920/2019 Page 3 Of 4 Underground Storage Tank Program OIR <br />, <br /> 1868 E . Hazelton Avenue Stockton , California 95205 T 209 468-3420 F 209 464-0136 1 www. sjcehd . conn <br />