Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> C 0 U N I Y <br /> Hazardous Materials Program Inspection Report <br /> Facility Name : T2388 <br /> acility Address: Date : <br /> UNITED PIPE & STEEL CORPORATION E Miner Ave , Stockton October 10 , 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I , CLASS II , or MINOR = Notice to Comply) <br /> Item # Remarks <br /> 5 HSC 25505 ( a) ( 1 ) Failed to complete and/or submit hazardous materials inventory for all reportable materials on site. <br /> One 330 gallon tote of diesel exhaust fluid was found on site that has not been reported . Any material that meets or <br /> exceeds the reportable quantity shall be reported in the facility's business plan . Immediately log into the California <br /> Environmental Reporting System (CERS) at http : Hcers . calepa . ca . gov/, add the materials to the hazardous material <br /> inventory, and submit to the EHD for approval . <br /> The Hazardous Materials Inventory form for the 55 gallon drum of stoddard solvent wrongly identifies the maximum <br /> amount present at the facility as 1 . 5 gallons and the average amount as . 06 gallons ; the location of the propane is <br /> wrongly identified as the north west corner of building vs . the north east corner of building . This information must be <br /> current and submitted as part of the business plan . Immediately log into the California Environmental Reporting <br /> System ( CERS) at http : //cers . calepa . ca . gov/, enter the correct or updated information , and submit to the EHD for <br /> approval . <br /> This is a minor violation. <br /> 6 HSC 25505 (a ) (2 ) Failed to complete and /or submit a site map with all required content . <br /> The map does not show the storm drain located at the west lot of the facility, the actual location of the propane has <br /> been moved to the north east area inside the building , does not show the location of the tote of diesel exhaust fluid , <br /> and the difference between the spill kit and the fire extinguishers has not been defined in the legend . A site map shall <br /> contain a north orientation , loading areas , internal roads , adjacent streets , storm and sewer drains , access and exit <br /> points , emergency shutoffs , evacuation staging areas , hazardous material handling and storage areas , and <br /> emergency response equipment . If a site map element is not applicable for your facility then list it on the map and <br /> label as " NA" . Immediately log into the California Environmental Reporting System (CERS) at <br /> http ://cers , calepa . ca . gov/, upload the correct or updated information , and submit to the EHD for approval . <br /> This is a minor violation. <br /> 11 HSC 25505 (a) (4) Failed to provide or document initial and/or refresher training to appropriate personnel . <br /> Employee training records were not available at the time of inspection . The business plan shall include provisions for <br /> ensuring that appropriate personnel receive initial and annual refresher training . This training shall be documented <br /> electronically or by hard copy and shall be made available for a minimum of three years . Immediately provide <br /> employee training for appropriate personnel and submit a copy of the training records to the EHD . <br /> This is a Class II violation. <br /> Overall Inspection Comments : <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation , and any supporting <br /> paperwork , within 30 days of receiving the completed inspection report . <br /> Starting September 1 , 2018 , all in-office CERS help will be provided at EHD hourly rate ($ 152 ) . To schedule an <br /> FA0024505 PRO542604 SCO01 10/10/2018 <br /> EHD 19-01 Rev. 09/27/2018 Page 2 of 3 Hazardous Materials Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468= 3420 1 F 209 464 -0138 1 www . sjcehd . com <br />