Laserfiche WebLink
ATC Associates Inc. <br /> 11.17 Lone Palm Avenue,Suite 201 <br /> Modesto,California 95351 <br /> 209-579-2221 <br /> fax:209-579-2225 <br /> ASS O C I ATE S INC . <br /> Due to the adoption of Resolution No. 2009-0042 by the State Water Resources Control Board <br /> (SWRCB), groundwater monitoring and sampling activities were reduced to a modified <br /> semiannual/biennial schedule. In a letter dated June 22, 2009, the San Joaquin County EHD <br /> requested to collect groundwater samples from wells MW-1, MW-4, MW-5, and MW-8 semi- <br /> annually and from all wells at the site biennially. Based on the request,the wells will be sampled <br /> using the schedule below. <br /> Odd Digit Years Even Digit Years <br /> First Quarter Third Ouarter First Quarter Third Quarter <br /> MW-1,MW-4, MW-1,MW-4, MW-1, MW-4, All wells <br /> MW-5, and MW-8 MW-5, and MW-8 MW-5, and MW-8 <br /> Additionally, the EHD granted ATC's request to discontinue analyzing groundwater samples <br /> collected from the site for di-isopropyl ether (DIPE), ethyl tertiary-butyl ether (ETBE), 1,2- <br /> dichloroethane (1,2-DCA), and 1,2-dibromoethane(EDB). <br /> Confirmation groundwater samples were collected from the site to evaluate the lateral and <br /> vertical extent of impacted groundwater beneath the site. A soil boring (SB-6) was advanced to <br /> first encountered groundwater to evaluate the lateral extent of impacted groundwater northwest <br /> of the source area. Two discrete grab groundwater samples (HP-1 and HP-2) were collected <br /> using a hydropunch sampling tool in the vicinity of CPT-2. HP-1 was advanced to an <br /> approximate depth of 45 feet bgs and HP-2 was advanced to an approximate depth of 70 feet bgs. <br /> MTBE was the only analyte of interest detected in the groundwater sample collected from SB-6. <br /> None of the analytes of interest were detected in the groundwater samples collected from HP-1 <br /> and HP-2. <br /> A soil gas study was conducted in September 2010 to evaluate the potential for soil vapor <br /> intrusion into the existing commercial structure located on-site. Based on the results of the soil <br /> gas study activities, there does not appear to be a risk to human health. <br /> SCOPE OF WORK <br /> Indoor Air Study <br /> ATC proposes to conduct indoor air sampling to evaluate air quality within the structure at the <br /> site. The sampling activities will be conducted on a normal business day to collect a <br /> representative indoor air samples that are consistent with routine activities associated with the <br /> commercial usage of the property. <br /> The indoor air sample will be collected using a one liter summa canister equipped with a <br /> certified flow control mechanism as provided by the analytical laboratory. The summa canister <br /> will collect the indoor air sample over a period of eight to ten hours and will be placed within the <br /> breathing zone for most adults, estimated to be approximately three to five feet above the interior <br /> floor. ATC will inventory and remove all indoor chemicals at least 48 hours prior to sampling, <br /> S:\Environmental\25847\37 Tracy\Reports\Workplans IA Wkpin.doc 3 ATC Associates Inc. <br />