Laserfiche WebLink
Page 13 <br /> X. AIR MONITORING <br /> A. KNOWN CONTAMINANTS - When air monitonng in the breathing zone(for a one minute <br /> duration)detects concentrations at the action level(s), introduce the appropriate action <br /> 1 Gasses and Vapors <br /> Action Level <br /> Instrument Calibration Frequency/ Above <br /> and date of Gas Duration of Air Background <br /> Calibration Standard Momtonn (Breathing Zone Action <br /> OVM(PID) 100 ppm Every 30 minutes Introduce engineering <br /> Isobutylene or sooner if controls (i a blower fans) <br /> RF = 0.70 odors detected 5 ppm vel D <br /> 100 ppm Don respirator vel C <br /> 500 22m Leave area vel C <br /> NE Upgrade to Level B <br /> 2 Explosion Hazard <br /> Action Level Above <br /> Instrument and Date Background Frequency/Duration <br /> of Calibration Ambient Air of Air Monitoring Action <br /> Combustible gas indicator Greater than 20% LEL Leave Area <br /> NE =NOT EXPECTED <br /> Parker Environmental Services, 4185 Rialto Court, Pittsburg, CA 94565-6116 <br /> Phone (510) 439-1024 Fax (510) 439-2566 <br />