Laserfiche WebLink
Page 17 <br /> XII. DECONTAMFNATION PROCEDURES <br /> A. Equipment (Sampling, Construction, Etc.)Decontamination (Solvents used, Equipment <br /> used, Method of Disposal) Attach site decontamination map as necessary. <br /> Equipment shall be cleaned.using Alconox rinsed twice with tap water and rinsed finally with <br /> distilled water Rnnseate will be stored in SS gallon drums <br /> B Personnel Decontamination (Solvents used, Method of solvent disposal, Include <br /> decontamination method of PPE and disposal of PPE) Attach site decontamination map as <br /> necessary <br /> Performed b,, rig with Alconox and potable water. Contaminated PPE will be disposed of in <br /> a waste containment dumpster. <br /> C Investigation derived material disposal <br /> 1 Drill cuttings/well water Stored on site. Soil cuttings stored in DOT 17-H steel <br /> drums Water stored in DOT 17-H steel drums Disposal at certified landfill facilities (soil)or <br /> by hump truck (water)depending on lab results. Material may also be remediated on site if <br /> on site remediation of soil or groundwater is chosen cleanup option <br /> 2 Decontamination Solutions Stored along with investigation well water in drums <br /> 3 Other PPE disposed of in trash dumaster. <br /> Legible and understandable precautionary labels must be affixed to containers of contaminated <br /> clothing, debris, waste, raw materials and mixtures <br /> Parker Environmental Services, 4155 Rialto Court, Pittsburg, CA 94565-6116 <br /> Phone (510) 439-1024 Fax (510) 439-2566 <br />