Laserfiche WebLink
e� <br /> t <br /> "? Two soil samples were collected from soil boring SB--2; one from a <br /> depth of five feet (SB2-51 ) and one from a depth of nine feet (SB2- <br /> 9' ) . Sample SB2-5' did not contain detectable concentrations of <br /> TPHg, TPHd, BTEX, Oil and Grease, or Purgeable Halocarbons. <br /> Cadmium, Chromium, Lead, Nickel, and Zinc were present at levels <br /> below their respective TTLCs and below ten times their respective <br /> STLCs. Chromium was detected at a concentration of 3.B0 ppm, Lead <br /> at a concentration of 8.79 ppm, Nickel at a concentration of 4.46 <br /> ppm, and Zinc at a concentration of 7.13 ppm, Cadmium was not <br /> detected in sample SB2-51 . TPHg and TPHd were detected in sample <br /> SB2--9' at concentrations of 220 ppm and 6.0 ppm, respectively. <br /> Beii?ene was detected at a concentration of 150 ppb, Toluene at a <br /> c=--: ntration of 620 ppb, Ethylbenzene at a concentration of 2400 <br /> ppb, and Xylenes at a concentration of 1400 ppb. oil and Grease <br /> was detected at a concentration of 34 ppm in sample SB2-91 . <br /> Purgeable Halocarbons were not detected. Cadmium, Chromium, Lead, <br /> Nickel, and Zinc were present at levels below their respective <br /> TTLCs and below ten times their respective STLCs. Cadmium was <br /> detected at a concentration of 0.174 ppm, Chromium at a <br /> concentration of 2.85 ppm, Lead at a concentration of 7.75 ppm, <br /> Nickel at a concentration of 3.32 ppm, and Zinc at a concentration <br /> of 5.90 ppm. <br /> Soil samples SB3-51 and SB3=9' were collected from soil boring SB-3 <br /> from, depths. of.five feet and nine..feet,.: respectively. TPHg, TPHd', <br /> BTEX, „Oi1 :and Grease, and 'Purgeable Halocarbons were- not detected:' <br /> v in ;either :of othe .soil samples:- Cadmium, Chromium, Lead, Nickel, <br /> `and Zinc were present at levels below their respective TTLCs and <br /> below ten times their respective STLCs in both samples. In sample <br /> ML <br /> SB3-5' , Chromium was detected at a concentration of 3.44 ppm, Lead <br /> at a concentration of 8.24 ppm, Nickel at a concentration of 4.10 <br /> ppm, and Zinc at a concentration of 7.99 ppm, In sample SB3-91, <br /> Chromium was detected at a concentration of 3.40, Lead at a <br /> concentration of 7. 17 ppm, Nickel at a concentration of 3.81 ppm, <br /> and Zinc at a concentration of 6.79 ppm. Cadmium was not detected <br /> in either sample. <br /> Two soil samples were collected from soil boring SB-4; one from a <br /> depth of five feet (SB4-5') and one from a depth of nine feet (SB4- <br /> 9' ) . Soil sample SB4-5' did not contain detectable concentratiora4: <br /> of TPHg, TPHd, BTEX, Oil and Grease, or Purgeable Halocarbons, <br /> Cadmium, Chromium, Lead, Nickel, and Zinc were present at levels <br /> below their respective TTLCs and below ten times their respective <br /> STLCs. Cadmium was detected at a concentration of 0.314 ppm, <br /> Chromium at a concentration of 4.02 ppm, Lead at a concentration of <br /> 7.38 ppm, Nickel at a concentration of 4.57 ppm, and Zinc at a <br /> concentration of 8.24 ppm. <br /> `� 275 GRANT LINE ROAD PAGE 15 <br />