Laserfiche WebLink
j 1 <br /> Appl/ed G005ystems 43255 Mission Boulevard, Fremont, CA 94539 (415)651•11106 <br /> FREMONT • COSTA MESA a SACRAMENTO r HOUSTON <br /> ANALYSIS REPORT <br /> 02121ab.frm <br /> Report Prepared for: Date Received: 5-14-88 <br /> Applied GeoSystems Laboratory Number:05038509 <br /> 4191-E Power Inn Road Project: 038032-1 <br /> Sacramento, CA 95826 Sample: S-4-LINE 9 <br /> Attention: Keith A. Romstad Matrix: Soil <br /> Parameter Result Detection Limit Date Notes <br /> (mg/kg) (mg/L) (mg/kg) (mg/L) Analyzed <br /> TVH as Gasoline NR <br /> TPA as Gasoline ND 2 05-16-88 <br /> TEH as Diesel NR <br /> Benzene ND 0.05 05-16-88 <br /> Toluene ND 0.05 05--16-88 <br /> Ethylbenzene ND 0.05 05-16-88 <br /> Total Xylenes 1 0.16 1 0.05 05-16-88 <br /> mg/kg = milligrams per kilogram = parts per million (ppm) . <br /> mg/L = milligrams per liter = ppm. <br /> ND = Not detected. Compoi,a;id(s) may be present at <br /> concentrations below the detection limit. <br /> NR = Analysis not required. <br /> PROCEDURES <br /> TVH/BTES--Total volatile hydrocarbons (TVH) and benzene, toluene, <br /> ethylbenzene, and total xylene isomers (BTEX) are measured by <br /> extraction according to EPA Metnod 5030 Followed by analysis by a <br /> EPA. Method 8020/602 (modified for TVH) which uses a gas chromato- <br /> graph (GC) equipped with a photo-ionization detector (PID) and a <br /> flame-ionization detector (FID) in series. Soil extracts and <br /> water samples are subjected to purge--and-trap introduction into <br /> the GC. <br /> TBH--Total petroleum hydrocarbons (low-to-medium boiling points) <br /> are measured by extraction according to EPA Method 5030 followed <br /> by analysis by a modified EPA Method 8015 which uses a GC <br /> equipped with an FID. Soil extracts and water samples are <br /> subjected to purge-and-trap introduction into the GC. <br /> TEA--Total extractable hydrocarbons (high boiling points) are <br /> measured by extraction according to EPA Method 35517 for soils or <br /> EPA .Method 3510 for water followed by a modified EPA Method 8015. <br /> with direct sample injection into a GG equipped with an FID. <br /> Tia Tran, Laboratory Supervisor Date Reported <br /> bi APPLIED GEOSYSTEMS IS CERTFXV BY THE STATE OF CAL1FORMA MPARTMENT OF HEALTH <br /> SERY!CES AS A HAZARDOUS WASTE TESTING LABORATORY <br />