PG&E TRACY SERVICE CENTER
STREET_NUMBER
502
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25027008
CURRENT_STATUS
01
SITE_LOCATION
502 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1441
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3.2.3.2 Soil Gas Sample Collection <br /> The subsurface gases were allowed to re-equilibrate for at least 72 hours after installation prior to <br /> sampling. As recommended by the Cal/EPA Advisory, the first soil gas probe sampled during <br /> the RI (A3-SG1) was purged for one, three, and seven volumes. A soil gas probe volume was <br /> calculated as the internal volume of the tubing and soil gas sampling implant along with the <br /> annulus of the auger boring around the soil gas sample point. The initial soil gas samples were <br /> collected in a one liter Tedlar bag after each discrete volume was purged and screened using a <br /> MiniRae 2000 PID, calibrated daily using 100 parts per million by volume (ppmv) isobutylene <br /> gas. The purge volume that correlated with the highest PID value was the volume purged at each <br /> sample location thereafter. One, three, and seven purge volumes from the A3-SG1 location <br /> yielded 400 ppmv, 467 ppmv, and 510 ppmv, respectively. Based on these concentrations, each <br /> soil gas probe sampled during the RI was purged for seven volumes immediately prior to <br /> sampling, which equates to approximately 54 milliliters for each probe. Purging was <br /> accomplished with a GilAir-58 air sampling pump equipped with a low-flow module calibrated <br /> to between 100 and 200 milliliters per minute (mL/min). <br /> Soil gas samples were collected into pre-cleaned, six-liter, flow-controlled, evacuated SUMMA® <br /> canisters. Canisters were connected to the 3-way valve located at the top of the soil gas probe <br /> with Teflon® tubing and threaded Swagelock unions. Dedicated flow-controllers for each <br /> sample were calibrated by the laboratory and placed in-line directly before each SUMMA® <br /> canister. Initial SUMMA® canister vacuum pressures prior to sampling were less than 28 inches <br /> of mercury. <br /> SUMMA® canisters were allowed to collect soil gas until the vacuum pressure measured within <br /> the canister was at minus three inches of mercury or less. After soil gas collection, the <br /> SUMMA® canister valve was shut, a brass cap was placed on the canister port, and the canister <br /> was packaged for delivery to Air Toxics, LTD., a State-certified laboratory. <br /> Soil gas samples were analyzed for VOCs by USEPA Method TO-15 with naphthalene and <br /> isobutane for the RI (Phase 1) sampling activities. For the SSI (Phase 2), soil gas samples were <br /> analyzed for VOC by USEPA Method TO-15 with naphthalene and helium. A total of three <br /> duplicate samples were collected immediately after the corresponding primary samples were <br /> collected. <br /> Each soil gas sample was named using an alphanumeric grid along with the sample location and <br /> the sample depth as shown in Figures 9 and 12. Soil gas sample locations are signified with <br /> "SG". For example, sample number A3-SG1 designates a soil gas sample collected from <br /> alphanumeric grid A3 from the first soil gas sample location(SG I). <br /> Leak Detection and Quality Assurance/Quality Control(QA/QC)Procedures <br /> Leakage during soil gas sampling could dilute samples with ambient air and produce results that <br /> underestimate actual site concentrations, or contaminate the sample with external contaminants. <br /> As such, each soil gas probe was leak checked in accordance with the test procedures described <br /> in Section 2.4 of the Cal/EPA Advisory — Active Soil Gas Investigations (DTSC, 2003). As <br /> specified in the guidance, leak tests were conducted at each soil gas point using a tracer <br /> compound. It should be noted that the DTSC was in the process of modifying the Advisory <br /> guidance between RI (Phase 1) and SSI (Phase 2) sampling at the Site. DTSC requested that <br /> PARSONS 22 FINAL RI REPORT-FORMER TRACY MGP <br /> APRIL 2010 <br />