Laserfiche WebLink
sTable 1 - Summary of VESOmical Analytical Data • <br /> Unocal Service Station No 6981 <br /> 4707 Pacific Avenue <br /> Stockton, California <br /> i <br /> Wellhead Influent Sample Results Effluent Sample Results <br /> Date TPHF� TPHg Benzene Benzene Toluene Ethylbenzene Xylenes MtBE TPHg3 TPHg Benzene Benzene Toluene Ethylbenzene Xylenes <br /> (mglm'} (PPmv} (mglm�} (PPmv) {mglm3) (Mg/M3) (mg/m� (mg/M) (mglm) (PPmv) (Mg/M3) (pPmv) (mg/m) (mgIm) (mglm3) <br /> 09-20-00 240 63 <0 50 <0 14 <0 50 085 075 93 <20 <05 <0 010 <0 003 023 0 13 079 <br /> 09-28-00 170 45 <0 10 <0 03 <0 10 020 040 72 <20 <0 5 <0 010 <0 003 <0 010 <0 010 <0 010 <br /> 10-25-00 295 78 <1 00 <0 29 <1 00 <1 00 <1 00 <100 <10 0 <26 <0 100 <0 029 <0 100 <0 100 <0 100 <br /> 10-30-00 160 42 <0 50 <0 14 <0 50 <0 50 <0 50 37 <10 <26 <0 10 <0 029 <0 10 <0 10 023 <br /> 11-28-00 293 77 <0 250 <0 07 0 864 0 823 504 <2 50 246 65 00352 001 0 387 0 705 451 <br /> 12-01-00 170 45 <0 50 <0 14 <0 50 <0 50 <0 50 <25 <10 <2 6 <0 10 <0 029 <0 10 <0 10 038 <br /> 12-15-00 180 47 <0 50 <0 14 <0 50 090 <0 50 38 <20 <05 <0 10 <0 029 <0 100 <0 100 <0 100 <br /> 12-21-00 200 53 <0 50 <0 14 065 <0 50 12 <2 5 <20 <05 <0 010 <0 003 <0 010 <0 010 <0 010 <br /> 01-23-01 <100 <2 6 <0 0500 <0 01 <0 0500 <0 0500 <0 0500 <0 500 <10 0 <26 <0 0500 <0 01 <0 0500 <0 0500 <0 0500 <br /> 01-31-01 System down due to mechanical failure <br /> mg/m3 = milligrams per cubic meter <br /> ppmv = parts per million by volume <br /> TPHg = Total Petroleum Hydrocarbons as gasoline <br /> MtBE = methyl tert-butyl ether <br /> NA = not analyzed for this constituent <br /> System shut down on 10/26/97 due to the failure of the flame detector The flame detector was replaced on 1215197,and the system operated approximadey 3 hours <br /> Influent and effluent samples were collected to confirm detector operation and destruction effeciency, then the system was shut down pending reciept of analytical data <br /> Dilution valve control motor replaced and system restarted on 12/21/97 <br /> 2 Sample of effluent inadvertently not collected on 3122199 <br /> S Sample also analyzed for methyl tert-butyl ether(<1 00 mg/m) <br /> 6 Sample also analyzed for methyl tert-butyl ether(<0 50 mg/m) <br /> 7 Service station facilities were removed Power to VES originally came off the main breaker panel for the service station Station demolition required anew service <br /> drop from power company, which was not completed until August 2000 <br /> Stockton to 6981 140124 04 <br />