STANDARD OPERATING PROCEDURE - <br /> GROUNDWATER SAMPLING <br /> T Gettler=Ryan Inc field personnel adhere to-the following procedures-for the collection-and-handling of <br /> groundwater samples prior to analysis by the analytical laboratory Prior to sample collection,the type of <br /> analysis to be performed is determined Loss prevention of volatile compounds is controlled and sample <br /> preservation for-subsequent-analysis is maintained <br /> Prior to sampling,the presence or absence of free-phase hydrocarbons is determined using an interface <br /> probe Product thickness,if present,is measured to the nearest 0 01 foot and is noted in the field notes In <br /> addition, all depth to water level measurements are collected with a static water level indicator and are <br /> also recorded in the field notes,prior to purging and sampling any wells <br /> After water levels are collected and nor to sampling, temperature, pH and electrical conductivity are <br /> co P P <br /> measured If purging is to occur, each well is purged a minimum of three well casing volumes of water <br /> using pre-cleaned pumps(stack,suction,Grundfos),or disposable bailers The measurements are taken a <br /> minimum of three times during the purging Purging continues until these parameters stabilize <br /> Groundwater samples are collected using disposable bailers The water samples are transferred from the <br /> bailer into appropriate containers Pre-preserved containers, supplied by analytical laboratones,are used • <br /> when possible When pre-preserved containers are not available,the laboratory is instructed to preserve <br /> the sample as appropriate Duplicate samples are collected for the laboratory to use in maintaining <br /> quality assurance/quality control standards The samples are labeled to include thejob number, sample <br /> identification,collection date and time,analysis,preservation(if any),and the sample collector's initials <br /> The water samples are placed in a cooler, maintained at 4°C for transport to the laboratory Once <br /> collected in the field,all samples are maintained under chain of custody until delivered to the laboratory_ <br /> The chain of custody document includes the job number,type of preservation,if any,analysis requested, <br /> sample identification, date and time collected, and the sample collector's name The chain of custody is <br /> signed and dated (including time of transfer) by each person who receives or surrenders the samples, <br /> beginning with the field personnel and ending with the laboratory personnel <br /> A laboratory supplied trip blank accompanies each sampling set and is labeled as QA For sampling sets <br /> greater than 20 samples, 5%trip blanks are included The trip blank is analyzed for some or all of the <br /> same compounds as the groundwater samples <br /> As requested by ConocoPhillips Company,the purge water and decontamination water generated during <br /> sampling activities is transported to ConocoPhillips - San Francisco Refinery, located in Rodeo, <br /> California <br /> bV0MU\C0n0WPh111jps-market50p OM47103 <br />