Laserfiche WebLink
Page 26 of 37 ' <br /> alscience <br /> ._nVironmental Glossary of Terms and Qualifiers , <br /> Aim aboratories, Inc. <br /> Work Order Number: 11-05-0194 , <br /> Qualifier Definition ' <br /> See applicable analysis comment. <br /> < Less than the indicated value. <br /> Greater than the indicated value. <br /> 1 Surrogate compound recovery was out of control due to a required sample dilution, ' <br /> therefore, the sample data was reported without further clarification. <br /> 2 Surrogate compound recovery was out of control due to matrix interference. The <br /> associated method blank surrogate spike compound was in control and, therefore,the ' <br /> sample data was reported without further clarification. <br /> 3 Recovery of the Matrix Spike (MS)or Matrix Spike Duplicate (MSD)compound was out <br /> of control due to matrix interference. The associated LCS and/or LCSD was in control <br /> and, therefore, the sample data was reported without further clarification. , <br /> 4 The MS/MSD RPD was out of control due to matrix interference. The LCS/LCSD RPD <br /> was in control and, therefore, the sample data was reported without further clarification. <br /> 5 The PDS/PDSD or PES/PESD associated with this batch of samples was out of control ' <br /> due to a matrix interference effect. The associated batch LCS/LCSD was in control and, <br /> hence, the associated sample data was reported without further clarification. <br /> 6 Surrogate recovery below the acceptance limit. <br /> 7 Surrogate recovery above the acceptance limit. ' <br /> B Analyte was present in the associated method blank. <br /> BU Sample analyzed after holding time expired. <br /> E Concentration exceeds the calibration range. ' <br /> ET Sample was extracted past end of recommended max. holding time. <br /> Analyte was detected at a concentration below the reporting limit and above the <br /> laboratory method detection limit. Reported value is estimated. <br /> ME LCS Recovery Percentage is within LCS ME Control Limit range. , <br /> ND Parameter not detected at the indicated reporting limit. <br /> Q Spike recovery and RPD control limits do not apply resulting from the parameter <br /> concentration in the sample exceeding the spike concentration by a factor of four or ' <br /> greater. <br /> X % Recovery and/or RPD out-of-range. <br /> Z Analyte presence was not confirmed by second column or GC/MS analysis. <br /> Solid - Unless otherwise indicated, solid sample data is reported on a wet weight basis, not , <br /> corrected for% moisture. All QC results are reported on a wet weight basis. <br /> ��^' " 7440 Lincoln Way, Garden Grove, CA 92841-1427 • TEL:(714)895-5494 FAX: 714 894-7501 <br />