Harding Lawson Associates <br /> SA4x6CC Vapor Phase Activated Carbon. Manufacturer's <br /> specifications and schematic drawings are presented in <br /> 4A* Attachment D. Treatment efficiency is 97 percent with <br /> a capacity to retain approximately 25 percent of it's <br /> own weight (500 pounds per reactor) based on <br /> manufacturer's specifications and published research. <br /> Typical operation of a VES utilizing activated carbon <br /> for treatment has a removal efficiency of approximately <br /> �► 97 percent. This is greatly affected by the relative <br /> humidity of the air stream as water vapor competes for <br /> adsorption sites. As long as the water separator is <br /> in-line with the VES prior to the first reactor, this <br /> efficiency can be maintained. With two reactors in <br /> series, the treatment efficiency increases to <br /> approximately 99 percent. At a 99 percent efficiency <br /> the calculated yield of the control equipment for the <br /> VES is <br /> i~ <br /> First day = 3 . 6 lbs (360 lbs x 0. 01) <br /> Second day = 1. 5 lbs (150 lbs x 0. 01) <br /> Third day = 0.8 lbs (80 lbs x 0.01) <br /> Fourth day = 0.2 lbs (20 lbs x 0. 01) <br /> �,. Continued operation should yield approximately 18 <br /> pounds per day which equates as 0. 18 lbs/day or 65. 7 <br /> pounds per year. Activated carbon will be replaced <br /> when the first reactor is unable to treat 90 percent of <br /> the inlet vapor concentrations or as the conditions of <br /> the permit specify. <br /> There is no power or fuel supply required for operation <br /> of the control equipment. <br /> 6. Locations and Amounts of Emissions <br /> There is one exhaust source for this VES. The exhaust <br /> stack extends from the top of the second carbon reactor <br /> to a height of ten feet above the <br /> g ground surface. The <br /> exhaust stack is a 4 inch diameter PVC pipe. The <br /> outlet flow rate is expected to be approximately 160- <br /> 180 CFM. The blower does have the capacity for a flow <br /> rate of 200 CFM and for the purposes of highest <br /> possible combinations, 200 CFM is used in these <br /> �.. calculations. The temperature of the exhaust gases is <br /> expected to be close to ambient air temperature with a <br /> �. slight rise due to the heat transfer from the blower. <br /> 032909P/R53 <br />