Laserfiche WebLink
f <br /> UUAB CORE LABORATORIES � <br /> r <br /> Q U A L I T Y A S S U R A N C E F 0 0 T E R <br /> Y METHOD REFERENCES ! <br /> 1 (1) EPA Sit-846, Test Methods for Evaluating Solid waste, Third Edition, September 1986, and Updates I, II, IIA, IIB, and III <br /> (2) Standard Methods for the Examination of Water and Wastewater, 18th Edition, 1992 <br /> (3) EPA 600/4-79-020, Methods of Chemical Analysis for Waters and Wastes, March 1983 <br /> (4) Federal Register, Friday, October 26, 1984 (40 CFR Part 136) <br /> ` (5) American Society for Testing and Materials. Volumes 5.01, 5.02, 5.03, 1992 <br /> (6) EPA 600/4-89-001, Short-term Methods for Estimating the Chronic Toxicity of Effluents and Receiving Waters to Fresh <br /> Water Organisms <br /> (7) EPA 600/4-90-027, Methods for Measuring the Acute Toxicity of Effluent and Receiving Waters to Fresh Water and Marine <br /> 'i. Organisms, Fourth Edition <br /> COMMENTS <br /> ALL methods of chemical analysis have a statistical uncertainty associated with the results_ Unless otherwise indicated, <br /> the data in this report are within the Limits of uncertainty as specified in the referenced method. Quality control <br /> acceptance criteria are based either on Limits specified in the referenced method or on actual laboratory performance. <br /> The date and time of analysis indicated on the QC report may not reflect the actual time of analysis for QC samples. Data <br /> reported in the QA report may be Lower than sample data due to dilution of samples into the calibration range of the analysis. <br /> Sample concentrations for solid samples are calculated on an as received (wet) basis unless otherwise indicated. Unless <br /> otherwise indicated, voLatiLes by gas chromatography (GC) are reported from a single column. Volatiles analyses by GC on low <br /> leve[ soils are conducted at room temperature. TCLP extractions are performed at sample amounts, approved by the State of <br /> California. <br /> FLAGS, FOOTNOTES, AND ABBREVIATIONS (as needed) <br /> NA = Not analyzed N.I. = Not Ignitable <br /> N/A = Not applicable S.I. = Sustains Ignition <br /> ug/L = Micrograms per Liter ICNS) = Ignites, but does not Sustain Ignition <br /> mg/L = Milligrams per liter RPD = Relative Percent Difference t <br /> ND = Not detected at a value greater than the reporting limit <br /> N NC = Not calculable due to values Lower than the detection Limit <br /> / (a) = Surrogate recoveries were outside acceptable ranges due to matrix effects. k <br /> (b) = Surrogate recoveries were not calculated due to dilution of the sample below the detectable range for the surrogate. <br /> (c) = Matrix spike recoveries were outside acceptable ranges due to matrix effects. <br /> (d) = Relative Percent Difference (RPD) for duplicate analysis outside acceptance limits due to actual differences in <br /> the sample matrix. <br /> (e) = The Limit Listed for flammability indicates the upper limit for the test. Samples are not tested at temperatures <br /> above 140 Fahrenheit since only samples which will sustain ignition at temperatures below 140 are considered <br /> flammable. <br /> (f) = Results for this hydrocarbon range did not match a typical hydrocarbon pattern. Results were quantified using a <br /> diesel standard, however, the hydrocarbon pattern did not match a diesel pattern. <br /> (g) = Results for this hydrocarbon range did not match a typical hydrocarbon pattern. Results were quantified using a <br /> gasoline standard, however, the hydrocarbon pattern did not match a gasoline pattern. <br /> (h) = High dilution due to matrix effects <br /> i <br /> QC SAMPLE IDENTIFICATIONS SUBCONTRACTED LABORATORY LOCATIONS <br /> MB = Method Blank SB = Storage Blank Core Laboratories: Aurora, Colorado *AU <br /> RB = Reagent Blank MS = Matrix Spike Casper, Wyoming *CA <br /> IC8 = Initial Calibration Blank MSD = Matrix Spike Duplicate Corpus Christi, Texas *CC <br /> CC8 = Continuing Calibration Blank MD = Matrix Duplicate Edison, New Jersey *ED <br /> CS = Calibration Standard BS = Blank Spike Houston, Texas (Env) *HE <br /> ICV = Initial Calibration SS = Surrogate Spike Houston, Texas (Pet) *HP <br /> Verification LCS = Laboratory Control Indianapolis, Indiana *IN <br /> CCV = Continuing Calibration Standard Lake Charles, Louisiana *LC <br /> verification RS = Reference Standard Long Beach, California *LB <br /> Valparaiso, Indiana *VP <br /> Bakersfield, California *BK <br /> 1250 Gene Autry [lay Autry Way <br /> Anaheim, CA 92805 <br /> . 1 <br /> (714) 937-1094 /u/matt/logs_n_forms/footer.form <br /> c:a.,:.n.ovai,.:,,rs m............:..:.:..n,aoo•>c..na,,,�,,.:,: ,,ar•r:.,;.,rm,o:,.•,o,:n,o,a„a:..:-,.n•,,..,..,.nw"n n,nuc ci,.,' io,W„n , <br /> f .,,o,,,..r ,: a -.•:r o:een,r.,,:.,.,,,es -.,,:,o:+v ., ,..'.•a' s „, ,:.n,:o........ <br /> r <br />