L CORE LABORATORIES
<br /> i
<br /> Q U A L I T Y A S S U R A N C k F 0 0 T E R
<br /> METHOD REFERENCES
<br /> (1) EPA SW-846, Test Methods for Evaluating Solid Waste, Third Edition, September 1986, and Updates I, I1, IIA, IIB, and III
<br /> (2) Standard Methods for the Examination of Water and Wastewater, 18th Edition, 1992
<br /> (3) EPA 600/4-79-020, Methods of Chemical Analysis for Waters and Wastes, March 1983
<br /> (4) Federal Register, Friday, October 26, 1984 (40 CFR Part 136)
<br /> (5) American Society for Testing and Materials, Volumes 5 01, 5 02, 5 03, 1992
<br /> (6) EPA 600/4-89-001, Short-term Methods for Estimating the Chronic Toxicity of Effluents and Receiving Waters to Fresh
<br /> Water Organisms
<br /> (7) EPA 600/4-90--027, Methods for Measuring the Acute Toxicity of Effluent and Receiving Waters to Fresh Water and Marine
<br /> Organisms, Fourth Edition
<br /> COMMENTS
<br /> ALL methods of chemical analysis have a statistical uncertainty associated with the results Unless otherwise indicated,
<br /> the data in this report are within the limits of uncertainty as specified in the referenced method Quality control
<br /> acceptance criteria are based either on Limits specified in the referenced method or on actual Laboratory performance
<br /> The date and time of analysis indicated on the QC report may not reflect the actual time of analysis for QC samples Data
<br /> reported in the QA report may be Lower than sample data due to dilution of samples into the calibration range of the analysis
<br /> Sample concentrations for solid samples are calculated on an as received (wet) basis untess otherwise indicated Unless
<br /> otherwise indicated, volatiles by gas chromatography (GC) are reported from a single column Volatiles analyses by GC on low
<br /> level soils are conducted at room temperature TCLP extractions are performed at sample amounts, approved by the State of
<br /> CaLifornia
<br /> FLAGS, FOOTNOTES, AND ABBREVIATIONS (as needed)
<br /> 0NA = Not analyzed N I = Not Ignitable
<br /> N/A = Not applicable S I = Sustains Ignition
<br /> ug/L. = Micrograms per Liter I(NS) = Ignites, but does not Sustain Ignition j
<br /> mg/L = MiLLigrams per liter RPD = Relative Percent Difference
<br /> ND = Not detected at a value greater than the reporting Limit
<br /> NC = Not calcutabte due to values Lower than the detection Limit
<br /> (a) = Surrogate recoveries were outside acceptable ranges due to matrix effects j
<br /> (b) = Surrogate recoveries were not calculated due to dilution of the sample below the detectable range for the surrogate
<br /> (c) = Matrix spike recoveries were outside acceptable ranges due to matrix effects
<br /> (d) = Relative Percent Difference (RPD) for duplicate analysis outside acceptance Lints due to actual differences in
<br /> the sample matrix
<br /> (e) = The Limit Listed for flammability indicates the upper Limit for the test Samples are not tested at temperatures
<br /> above 140 Fahrenheit since only samples which will sustain ignition at temperatures betow 140 are considered
<br /> flammable
<br /> (f) = Results for this hydrocarbon range did not match a typical hydrocarbon pattern Results were quantified using a
<br /> diesel standard, however, the hydrocarbon pattern did not match a diesel pattern
<br /> (g) = Results for this hydrocarbon range did not match a typicat hydrocarbon pattern Results were quantified using a
<br /> gasoline standard, however, the hydrocarbon pattern did not match a gasoline pattern
<br /> (h) = High dilution due to matrix effects
<br /> QC SAMPLE IDENTIFICATIONS SUBCONTRACTED LABORATORY LOCATIONS
<br /> MB = Method Blank SB = Storage Blank Core Laboratories Aurora, Colorado *AU
<br /> RB = Reagent Blank MS = Matrix Spike Casper, Wyoming *CA
<br /> ICB = Initial Calibration BLank MSD = Matrix Spike Duplicate Corpus Christi, Texas *CC
<br /> CCB = Continuing Calibration Btank MD = Matrix Duplicate Edison, New Jersey *ED
<br /> CS = Calibration Standard BS = Blank Spike Houston, Texas (Env) *HE
<br /> ICV = InitiaL Calibration SS = Surrogate Spike Houston, Texas (Pet) *HP
<br /> Verification LCS = Laboratory ControL Indianapolis, Indiana *IN
<br /> CCV = Continuing Calibration Standard Lake Charles, Louisiana *LC
<br /> verification RS = Reference Standard Long Beach, California *LB
<br /> vatparaiso, Indiana *VP
<br /> Bakersfield, California *BK
<br /> 1250 Gene Autry Way Autry Way
<br /> Anaheim, CA 92805
<br /> (714) 937-1094 /u/matt/Logs n forms/footer form
<br /> The analylce resu115 oPnO s o nlerpe[a1 ons cpnla netl n Ih s epprl a a basntl pppn nlprmat pn and m,ter el by llw cl rinl to whose eKcl-we arrd cpnlbenl al psi to s lepell nam 1JnPn md110 fnqvlcal ns Aln u[.+ni.ns pr n10r0 els nOns
<br /> paa�Sep rupre5enl the oast N[lgmgnt 61 C.v Lab Op Co-e Lab.plw 1 pwevn makgy no wi rimy n e[—1.1 r a o ss pr {r{.of any Type arrtl eMp essty u..cla ms sflmu as to Ina Wud ct 1,'..
<br /> ,,y
<br /> r M a1 o s d pros Ia[aouess.I
<br /> any pa qsa gyp. nll or m ural p.puny well,m,d n....ml on w Ill canon such thls mport shall not tle ep O j n whole pr n pa t w IhW t I v w tl s{I to of Co "a ral,be