Laserfiche WebLink
o FLUOR DANIEL GTI <br /> July 11, 1997 <br /> Mr Bob DeNinno <br /> The Southland Corporation <br /> 19033 West Valley Hwy , D-104 <br /> Kent, WA 98032 <br /> Subject Second Quarter 1997 Monitoring and Sampling Report <br /> Southland Site No 20304 <br /> 455 Grant Line Road <br /> Tracy, California <br /> Fluor Daniel GTI Project 02070 0456 <br /> Dear Mr DeNmno <br /> This Second Quarter 1997 Monitoring and Sampling Report presents the results of monitoring and <br /> sampling activities performed by Fluor Daniel GTI, Inc (Fluor Daniel GTI) at the subject site (Figures 1 <br /> and 2, Attachment 1) on May 12, 1997 Activities conducted during this reporting period are summarized <br /> below <br /> ■ Depth to water(DTW)was gauged in 11 groundwater monitoring wells and three <br /> groundwater extraction wells (Figure 2) <br /> ■ Groundwater samples were collected from five wells MW-4, MW-5, MW-8,MW-9, and <br /> MW-10, and submitted to a certified laboratory for analysis for benzene,toluene, <br /> ethylbenzene and xylenes (BTEX), methyl-tert-butyl-ether(MTBE), and total petroleum <br /> hydrocarbons-as-gasoline (TPH-G) <br /> Groundwater Monitoring Data <br /> Groundwater monitonng was performed on May 12, 1997 Prior to monitoring, the well caps were <br /> opened to allow the water level in each well to stabilize to atmospheric pressure The DTW was <br /> o1560297 RPT(STHL 5 1) <br /> 757 Arnold Drive, Suite D / Martinez, CA 94553 USA (510) 370-3990 FAX(510) 370-3991 <br />