• 2 . 0 GROUNDWATER FLOW DIRECTION AND GRADIENT <br /> On July 30, 2004, ASE measured the depth to water in six site groundwater <br /> monitoring wells using an electric water level sounder The surface of the <br /> groundwater was also checked for the presence of free-floating <br /> hydrocarbons or sheen No free-floating hydrocarbons or sheen were <br /> observed in any of the site groundwater monitoring wells As requested <br /> by the San Joaquin County PHS-EHD, the groundwater sampling w a s <br /> coordinated with the consultants investigating two adjacent properties, the <br /> former BP Service Station located at 2375 Tracy Boulevard to the west and <br /> the former Chevron Station located at 575 Grant Line Road to the north <br /> Groundwater elevation data from the three sites are presented in Tables <br /> One, Two, and Three <br /> A groundwater potentiometric surface map that includes groundwater <br /> elevation data from all of the monitoring wells in the area is presented as <br /> Figure 2 The groundwater flow direction is to the northwest with a <br /> gradient of approximately 0 006 ft/ft This gradient and flow direction are <br /> consistent with previous findings <br /> 3 . 0 GROUNDWATER SAMPLE COLLECTION AND ANALYSIS <br /> Prior to sampling, each well was purged of three well casing volumes of <br /> groundwater using disposable polyethylene bailers Petroleum <br /> hydrocarbon odors were noted during the purging and sampling of <br /> monitoring wells MW-1 and MW-2 The parameters pH, temperature, and <br /> conductivity were monitored during the well purging, and samples were <br /> not collected until these parameters stabilized Groundwater samples were <br /> collected from each well using the same disposable polyethylene bailers <br /> and were decanted from the bottom of the bailers using low-flow <br /> emptying devices into 40-m1 volatile organic analysis (VOA) vials, pre- <br /> preserved with hydrochloric acid The samples were capped without <br /> headspace, labeled and placed in a cooler with wet ice for transport to Kiff <br /> Analytical, LLC of Davis, California (ELAP #2236) under appropriate chain- <br /> of-custody documentation Well sampling field logs are presented in <br /> Appendix A <br /> The groundwater samples were analyzed for total petroleum hydrocarbons <br /> as gasoline (TPH-G), benzene, toluene, ethyl benzene, and total xylenes <br /> (collectively known as BTEX), and fuel oxygenates by EPA Method 8260 <br /> Analytical data from the three sites are presented as Tables Four, Five, a n d <br /> Six The certified analytical report and chain-of-custody documentation <br /> Singh's Unocal Service Station Quarterly Report — July 2004 Sampling <br /> -2- <br />