My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
3500 - Local Oversight Program
>
PR0545208
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2020 4:27:06 PM
Creation date
1/27/2020 4:08:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0545208
PE
3528
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
02
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Shell Sites <br /> Page 2 <br /> 2320 El Dorado Street,Stockton <br /> An SCM was submitted on November 4, 2005. Shell thinks the hydrocarbons are migrating across <br /> El Dorado Street from the site at 2315 El Dorado Street. TCE and PCE have been detected in the <br /> water samples collected from the Shell site monitoring wells. The source of these contaminants is <br /> unknown. Shell requested that the site at 2315 El Dorado be directed to add analysis for TCE and <br /> PCE to the suite of constituents being analyzed for in that sites water samples. At this time EHD <br /> will wait for data from Shell indicating 2315 El Dorado is the source of the TCE and PCE since the <br /> current data discussed below doesn't support Shell's request. <br /> EHD previously completed a cursory review of the history and investigation of the former waste oil <br /> underground storage tank (UST) tank at the 2315 El Dorado Street. In April 1987, a 200-gallon <br /> waste oil UST was removed from the site. Analytical results of the soil sample collected beneath the <br /> UST were non-detect (ND) for TCE and 1.6 micrograms per kilogram (ug/kg) of PCE. In October <br /> 1993 multiple soil samples were collected from 3 soil borings to 30 feet below surface grade (bsg) <br /> and 1 soil boring to 36 feet bsg that were installed next to the former UST. Analytical results of all <br /> the samples were ND for PCE and TCE. Analytical results of a ground water sample from <br /> monitoring well MW-1 installed next to the former UST in September 1994 were also ND for PCE <br /> and TCE. EHD also reviewed our Shell station UST file and found that Shell originally reported a <br /> 550 gallon waste oil UST to be at the site, but when EHD staff inspected the site in 1986 it was <br /> stated that the UST had been removed prior to 1984 so there is no soil data on the Shell waste oil <br /> UST. The file did have soil sample results from the UST system removal in July 1990 and soil <br /> samples SS-1, 5, 7, 10, 11 and 12 all had detections of PCE in the soil samples collected. Shell plans <br /> to request a review of our files for both sites. Shell needs to provide information showing the <br /> location of their former waste oil tank and that it was removed prior to 1984. <br /> Currently, there is no monitoring well placed down-gradient of the current UST system. Shell is to <br /> submit a work plan for installation of a monitoring well down-gradient of the current UST system. <br /> In addition, Shell may want to propose installation of an up-gradient well near the 2315 El Dorado <br /> site to gather additional data. <br /> 2494 Fremont Street Stockton <br /> After a report of the most recent site work is submitted to EHD for review, EHD will provide <br /> comments on whether further investigation is necessary. <br /> 2375 Grant Line Trac <br /> An SCM is being prepared for this site. Periodic vacuum extraction operation has been initiated and <br /> a proposal of frequency and rate of pumping is to be included in the SCM. Shell will discuss with 7- <br /> Eleven submitting a co-mingled plume application. A sampling program for analyzing for MTBE, <br /> TBA and TAME in the water samples from the monitoring wells on a quarterly basis and adding <br /> analysis for BTEX,TPH and other oxygenates annually on the water samples will be prepared. <br /> 1071 Main Street,Manteca <br /> A site closure report submitted on September 19, 2005,is being reviewed by EFID. After review of <br /> the report discontinuance of quarterly monitoring will be decided. <br /> 341 Main Street Ripon <br /> EHD responded to the closure report prepared for this site. Collection of additional soil data or <br /> preparation of a site model should be completed to justify closure. <br /> 7700 Moreland Street, Stockton <br /> A deep monitoring well was to be installed on November 14,2005. <br />
The URL can be used to link to this page
Your browser does not support the video tag.