Laserfiche WebLink
RECEIVED MAY g 1983 <br /> SEQUOIA ANALYTICAL <br /> 680 Chesapeake Drive • Redwood City, CA 94063 <br /> (415) 364-9600 - FAX(415) 364-9233 <br /> i+vnv . O } S rr r ry:v n . y r ni r him 7 r x S, <br /> RESNA r x ' ` '`r v yClient Project ID W0322 00, JB Terminal } n� Af $arnpled Apr 23','199d ' <br /> ,1710 Main Street Sample Matrix Water Received May 5, 1993 <br /> Escalon, CA 95320 Analysis Method EPA 5030/8015/8020 Reported May 13, 1993 } <br /> Attention Lois Frantz First Sample# 3E15401 <br /> }Cv wry f x u.n++ x}v nr. ,. v 4: yr vasrr xr v +~ rrr tv 4 vvr r r " v r f v ryr rr + wx + +n rr v <br /> TOTAL PURGEABLE PETROLEUM HYDROCARBONS with BTEX DISTINCTION <br /> Reporting Sample Sample Sample Sample Sample Sample <br /> Analyte Limit I.D. I.D. I D. I.D. 1 D. I D. <br /> Fig/L 3E15401 3E15402 3E15403 3E15404 <br /> JBT MW-2 JBT MW-3 JBT MW-4 JBT MW-5 <br /> Purgeable <br /> Hydrocarbons 50 N D N D N D N D <br /> Benzene 050 N D N D N D N D <br /> Toluene 050 N D N D N D N D <br /> Ethyl Benzene 0 50 N D. N D N D N D <br /> Total Xylenes 050 N D N D N D N D <br /> Chromatogram Pattern -- -- -- -- <br /> Quality Control Data <br /> Report Limit Multiplication Factor 10 10 -10 10 <br /> Date Analyzed 5/6/93 5/6/93 5/6/93 5/6/93 <br /> Instrument Identification GCHP-2 GCHP-2 GCHP-2 GCHP-2 <br /> Surrogate Recovery, % 108 111 108 110 <br /> (QC Limits = 70-130%) <br /> Purgeable Hydrocarbons are quantttated against a fresh gasoline standard <br /> Analytes reported as N D were not detected above the stated reporting limit <br /> SEQUOIA ANALYTICAL <br /> Ana zm_ <br /> Vickie Tagfib <br /> Project Manager 3E15401 WAT <1> <br />