Laserfiche WebLink
I]0 2nd Avenue South #D7 Pacheco,CA 94553-5560 <br /> [A�M:cC�ampbellAnalybcal Inc Teteplrone 925-798 1620 Fax 925-798-1622 <br />' http 11www mccampWl corn E-marl main a mccampbell corn y <br /> QC SUMMARY REPORT FOR SW8015C <br /> 1 <br /> Matrix W WorkOrder 0212368 <br />' EPA Method SW8015C Extraction SW3510C BatchlD 5425 Spiked Sample ID NIA <br /> Compound <br /> Sample Spiked MS* MSD` MS-MSD' LCS LCSD LCS-LCSD Acceptance Criteria(%) <br />' pg1L Ng/L % Rec % Ree % RPD %ReC %ReC % RPD Low Nigh <br /> TPH(d) N/A 7500 N/A N/A N/A 111 113 2 55 70 T-130 <br />' %SS N/A 100 N/A N/A NIA 113 113 { 0332 70 130 <br /> All target compounds in the Method Blank of this extraction batch were ND less than the method RL with the following exceptions <br /> NONE <br /> 1 <br /> 1 <br /> lie <br /> I <br /> I <br /> I <br /> I ' <br /> MS=Matrix Spike MSD=Matrix Spike Duplicate LCS=Laboratory Control Sample LCSD=Laboratory Control Sample Duplicate RPD=Relative Percent <br />' Deviation <br /> NIA=not enough sample to perform matnx spike and matrix spike duplicate <br /> NR=analyte concentration in sample exceeds spike amount for soil matrix or exceeds 2x spike amount for water matrix or sample diluted due to high matrix or <br /> 0 analyte content <br /> %Recovery=100'(MS Sample)/(Amount Spiked) RPD=100"(MS—MSD)/(MS+MSD)"2 <br /> 'MS and!or MSD spike recoveries may not be near 100%or the RPDs near 0%if a)the sample is inhomogenous AND contains significant concentrations of <br /> analyte relative to the amount spiked or b)if that specific sample matrix interferes with spike recovery <br />