SANJOAQUIN Environmental Health Department <br /> COUNTY <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TRACY FORD 3500 AUTO PLAZA WAY, TRACY September 10, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 403 CCR 66265.173 Failed to keep hazardous waste containers closed except when adding or removing hazardous <br /> waste. <br /> -One black metal 55 gallon drum of oily solids located on the spill pallet was observed open without the lid on. <br /> -One black metal 55 gallon drum of oily solids located in the hazardous waste storage room was observed without a <br /> locking ring securely closing the drum <br /> All hazardous waste containers shall be closed at all times except when adding or removing waste. Immediately <br /> close these containers and ensure all hazardous waste containers are closed when not adding or removing waste. <br /> This is a repeat violation, Class II. <br /> 507 CCR 66265.195 Failed to conduct daily inspections of hazardous waste tank system and maintain records onsite. <br /> Daily inspections of the discharge systems, monitoring equipment, and tank levels were not documented and <br /> maintained on site. Only the current month of daily tank inspections were available for review during the inspection. <br /> Immediately begin to conduct daily inspections of the discharge systems, monitoring equipment, and tank levels for <br /> all tanks containing hazardous waste and maintain written records on site for 3 years. <br /> This is a Class II violation. <br /> 512 CCR 66265.192(h)Failure to obtain an assessment or reassessment of a hazardous waste tank system. <br /> Facility does not have a tank reassessment for the 500 gallon used oil tank and the 100 gallon used antifreeze tank. <br /> Last available tank assessment is from July 22,2010. Service Manager states that the tank assessment is currently <br /> in process. The owner or operator of a hazardous waste tank shall obtain a written assessment reviewed and <br /> certified by an independent,qualified, professional engineer, registered in California attesting that the system has <br /> sufficient structural integrity, is acceptable for the transferring,storing, and treating of hazardous waste, and that the <br /> tanks and containment system are suitably designed. Immediately have a reassessment prepared for the 500 <br /> gallon used oil tank and the 100 gallon waste antifreeze tank. Submit a copy of the final tank assessment to the <br /> EHD. <br /> This is a Class II violation. <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. <br /> One black metal 55 gallon drum of oily solids was observed in the hazardous waste storage area without an <br /> accumulation start date on the label. All hazardous waste containers shall be marked with the following information: <br /> -the words"Hazardous Waste" <br /> -name and address of generator <br /> -hazardous properties <br /> -physical state <br /> -composition(contents) <br /> -accumulation start date <br /> Immediately label these containers and ensure that all hazardous waste containers are marked with all the required <br /> information. <br /> This is a repeat violation, Class ll. <br /> FA0010988 PR0514484 SCO01 09/10/2018 <br /> EHD 22-02 Rev.10/31/2017 Page 5 of 6 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />