F026 Wastes (except wastewater and spent carbon from hydrogen chloride purification) from the f
<br /> production of materials on equipment previously used for the manufacturing use (as a reactant, chemical
<br /> intermediate, 6'r component in a formulating process) of tetra-, penta-, or hexachlorobenzene under alkaline i
<br /> conditions.
<br /> F027 --''Discarded unused formulations containing tri-, tetra-, or pentachlorophenol or discarded unused
<br /> formulations containing compounds derived from these chlorophenols. (This listing does not include-formulations
<br /> containing hexachlorophene synthesized from prepurified 2,4,5-trichlorophenol as the sole component.)
<br /> F028 Residues resulting from the incineration or thermal treatment of soil contaminated with EPA
<br />` Hazardous Waste Nos. F020, F021, F022, F023, F026, and F027.
<br /> F032 ''':Wastewaters (except those that have not come in contact with process contaminants), process
<br /> residuals, preservative drippage, and spent formulations from wood preserving processes generated at plants that
<br /> currently use or' have previously used chlorophenolic formulations (except potentially cross-contaminated wastes
<br /> that have had ijthe F032 waste code deleted in accordance with § 261.35 of this chapter or potentially cross-
<br /> contaminated regulated as hazardous wastes (i.e., F034 or F035), and where
<br /> contaminated wastes that are otherwise y
<br /> the generator does not resume or initiate use of chlorophenolic formulations). This listing does not include K001
<br /> bottom sediment sludge from the treatment of wastewater from wood preserving processes that use creosote
<br /> and/or pentachlorophenol I
<br /> F034 -1k Wastewaters (except those that have not come in contact with process contaminants), process
<br /> residuals, preservative drippage, and spent formulations from wood preserving processes generated at punts that
<br /> t use creosoteifformulations. This listing does not include K001 bottom sediment sludge from the treatment of
<br /> wastewater from wood preserving processes that use creosote and/or pentachlorophenol.
<br /> F035 Wastewaters (except those that have not come in contact with process contaminants), process
<br /> residuals, preservative drippage, and spent formulations from wood preserving processes generated at plants that
<br /> use inorganicpreservatives containig arsenic or chromium. This listing does not include K001 bottom sediment
<br /> sludge from the treatment of wastewater from wood preserving processes that use creosote and/or
<br /> pentachlorophenol.
<br /> F037 ► Petroleum refinery primary oillwater/solids separation sludge - any sludge generated from the
<br /> gravitational separation of oil/water/solids during the storage or treatment of process wastewaters and oily cooling
<br /> wastewaters from petroleum refineries. Such sludges include, but are not limited to, those generated in:
<br /> ail/watedsolid5`separators; tanks and impoundments; ditphes'and other conveyances; sumps; and stormwater units
<br /> recieving dry,weather flow. Sludge generated in stormwater units that do not receive dry weather flow, sludges
<br /> generated from non-contact once-through cooling waters segregated for treatment from other process or oily
<br /> cooling waters;;"1 sludges generated in agressive biological treatment units as defined in § 261.31 (b)(2) (including
<br /> sludges generated in one or more additional units after wastewaters have been treated in agressive biological
<br /> treatment units) and K051 wastes are not included in this listing.
<br /> F038 Petroleum refinery secondary (emulsified) oil/water/solids separation sludge- Any sludge and/or
<br /> float generated from the physical and/or chemical separation of oillwater/solids in process wastewaters and oily
<br /> cooling wastewaters from petroleum refineries. Such wastes include, but are not limited to, all sludges and floats
<br /> generated in: induced air flotation (IAF) units, tanks and impoundments, and all sludges generated in DAF units.
<br /> 1 Sludges generated in stormwater units that do not receive dry weather flow, sludges generated from non-contact
<br /> once-through cooling waters segregated for treatment from other process or oily cooling waters, sludges and floats
<br /> generated in agressive biological treatment units as defined in § 261.31 (b)(2) (including sludges and floats
<br /> generated in one or more additional units after wastewaters have been treated in agressive biological treatment
<br /> units) and F037, K048, and K051 wastes are not included in this listing.
<br /> I F039 I Leachate (liquids that have percolated through land disposed wastes) resulting from the disposal of
<br /> more than one restricted waste classified as hazardous under subpart D of this part. (Leachate resulting from the
<br /> disposal of one or more of the following EPA Hazardous Wastes and no other Hazardous Wastes retains its EPA
<br /> Hazardous Number(s): F020, F021, F022, F026, F027, and/or F028.).
<br /> �. .y K0011'Pentachlorophenol, phenol, 2-chlorophenol, p-chloro-m-cresol. 2,4-dimethylphenyl, 2,4-
<br /> dinitrophenol, trrchlorophenois, tetrachlorophenols, 2,4-dinitrophenol, cresosote, chrysene, naphthalene,
<br /> fluoranthene, benzo(b)fluorathene, benzo(a)pyrene, indeno(1,2,3-cd)pyrene, benz(a)anthracene,
<br /> dibenz(a)anthracene, acenaphthalene.
<br /> K002!- Hexavalent chromium, lead.
<br /> K003 L Hexavalent chromium, lead.
<br /> K004 Hexavalent chromium.
<br /> K005 '- Hexavalent chromium, lead.
<br /> 3
<br />
|