Laserfiche WebLink
Sequoia 680 Chesapeake Dnve Pedwood City,CA 94063 (415) 364 9600 FAX(415) 364 9233 <br /> 404 N Wiget Lane Walnut Creek CA 94598 (510) 988 9600 FAX(510)988 9673 <br /> fruit' Analytical 819 5tnker Avenue Suite 8 Sacramento CA 95834 (916) 921 9600 FAX(916) 921 0100 <br /> SoUchstone Developments Client Project ID Chevron #9-4183 <br /> 781 Kingston Ave Matrix Solid <br /> Oakland, CA 94611 <br /> Attention Robert Mallory QC Sample Group 6041944-948 Reported May 6, 1996 <br /> QUALITY CONTROL DATA REPORT <br /> Analyte Benzene Toluene Ethyl Xylenes Diesel Oil & <br /> Benzene Grease <br /> QC Batch# SP050196 SPOS0196 SP050196 SP050196 SP042996 SPOS0196 <br /> 8020EXA 8020EXA 8020EXA 8020EXA 8015EXA 5520MDA <br /> Analy Method EPA 8020 EPA 8020 EPA 8020 EPA 8020 EPA 8015 SM 5520 <br /> Prep Method EPA 5030 EPA 5030 EPA 5030 EPA 5030 EPA 3550 SM 5520 <br /> Analyst L Huang L Huang L Huang L Huang J Dinsay D Newcomb <br /> MS/MSD # 6041572 6041572 6041572 6041572 6041763 6041944 <br /> Sample Conc N D N D N D N D N D N D <br /> Prepared Date 5/1/96 5/1/96 5/1/96 5/1/96 4/29/96 5/1/96 <br /> Analyzed Date 5/1/96 5/1/96 5/1/96 5/1/96 4/29/96 5/1/96 <br /> Instrument I D # HP-4 HP-4 HP 4 HP-4 HP 3A Manual <br /> Conc Spiked 0 40 mg/kg 0 40 mg/kg 0 40 mg/kg 1 2 mg/kg 10 mg/kg 5000 mg/kg <br /> Result 033 036 035 11 10 5000 <br /> MS % Recovery 83 90 88 92 100 100 <br /> ODup Result 037 039 037 12 91 4400 <br /> MSD % Recov 93 98 93 100 91 88 <br /> RPD 11 80 56 87 94 13 <br /> RPD Lima 0-50 0-50 0-50 050 0-50 0-30 <br /> LCS # 4LCS050196 4LCS050196 4LCS050196 4LCS050196 LCSO42996 BLK050196 <br /> Prepared Date 5/1/96 5/1/96 5/1/96 5/1/96 4/29/96 5/1/96 <br /> Analyzed Date 5/1/96 5/1/96 5/1/96 5/1/96 4/29/96 5/1/96 <br /> Instrument I D # HP-4 HP-4 HP-4 HP-4 HP-3A Manual <br /> Conc Spiked 20ug/L 20ug/L 20ug/L 60ug/L 10 mg/kg 5000 mg/kg <br /> LCS Result 17 18 18 54 87 5000 <br /> LCS % Recov 85 90 90 90 87 100 <br /> LCS <br /> Control Limits 55-145 47-149 47-155 56-140 50-150 60-140 <br /> Please Note <br /> The LCS is a control sample of known,interferent free matrix that is analyzed using the same reagents, <br /> SEQUOIA ANALYTICAL, #1271 preparation,and analytical methods employed for the samples The matrix spike is an aliquot of sample <br /> fortified with known quantities of specific compounds and subjected to the entire analytical procedure If <br /> V�Y the recovery of analytes from the matrix spike does not fall within specified control limas due to matrix <br /> 1 interference,the LCS recovery is to be used to validate the batch <br /> Kevin Van Slambrook **MS=Matrix Spike, MSD=MS Duplicate, RPD=Relative%Difference <br /> Project Manager <br /> 6041944 TUD <11 n <br />