My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0002116
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
236
>
2900 - Site Mitigation Program
>
PR0001333
>
ARCHIVED REPORTS_XR0002116
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2020 11:48:11 AM
Creation date
1/29/2020 11:22:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0002116
RECORD_ID
PR0001333
PE
2950
FACILITY_ID
FA0004067
FACILITY_NAME
CHEVRON SERVICE STA 9-4183 (INACT)
STREET_NUMBER
236
Direction
N
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03710028
CURRENT_STATUS
02
SITE_LOCATION
236 N HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
179
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sequoia 680 Chesapeake Drive Redwood City CA 94063 (415) 364 9600 FAX(415) 364 9233 <br /> 404 N Wiget Lane Walnut Creek CA 94598 (510) 988 9600 FAX(510)988 9673 <br /> Analytical 819 Striker Avenue,Stole 8 Sacramento, CA 95834 (916) 921 9600 FAX(916)921 0100 <br /> Souchstone Developments Client Project Ib Chevron #9-4183 <br /> 781 Kingston Ave Matrix Solid <br /> Oakland, CA 94611 <br /> Attention Robert Mallory QC Sample Group 6041944-948 Reported May 6, 1996 <br /> QUALITY CONTROL DATA REPORT <br /> Analyte Acenaphthene 4-Nitrophenol 2,4-Dinitro- Pentachloro Pyrene <br /> toluene phenol <br /> OC Batch# SP042996 SP042996 SP042996 SP042996 SP042996 <br /> 8270EXA 8270EXA 8270EXA 8270EXA 8270EXA <br /> Analy Method EPA 8270 EPA 8270 EPA 8270 EPA 8270 EPA 8270 <br /> Prep Method EPA 3550 EPA 3550 EPA 3550 EPA 3550 EPA 3550 <br /> Analyst T Granicher T Granicher T Granicher T Granicher T Granicher <br /> MS/MSD # 6041872 6041872 6041872 6041872 6041872 <br /> Sample Conc N D N D N D N D N D <br /> Prepared Date 4/29/96 4/29/96 4/29/96 4/29/96 4/29/96 <br /> Analyzed Date 4/30/96 4/30/96 4/30/96 4/30/96 4/30/96 <br /> Instrument I D # GC/MS-1 GC/MS-1 GC/MS 1 GC/MS-1 GC/MS-1 <br /> Conc Spiked 2500 ug/kg 5000 ug/kg 2500ug/kg 5000 ug/kg 2500 ug/kg <br /> Result 2900 2100 1300 4800 3400 <br /> MS % Recovery 116 42 50 95 136 <br /> Dup Result 3200 2100 1600 5900 4000 <br /> SD % Recov 128 42 64 118 160 <br /> RPD 98 00 25 22 16 <br /> RPD Limit 0-19 0-50 0-47 0-47 0-36 <br /> LCS # I-CS050196 LCS050196 LCS050196 LCS050196 LCS050196 <br /> Prepared Date 5/1/96 5/1/96 5/1/96 5/1/96 5/1/96 <br /> Analyzed Date 5/2/96 5/2/96 5/2/96 5/2/96 5/2/96 <br /> Instrument I D# GC/M8-1 GC/MS-1 GC/MS-1 GC/MS-1 GC/MS-1 <br /> Conc Spiked 2500yg/kg 5000ug/kg 2500 ug/kg 5000ug/kg 2500ug/kg <br /> LCS Result 2300 3300 1800 3500 2500 <br /> LCS % Recov 92 66 70 70 98 <br /> LCS 50-140 20-120 20-120 30-110 50-115 <br /> Control Limits <br /> Please Note <br /> The LCS is a control sample of known,interferent free matrix that is analyzed using the same reagents, <br /> preparation,and analytical methods employed for the samples The matrix spike is an aliquot of sample <br /> S, QUOIA ANALYTICAL, #1271 fortified with known quantities of specific compounds and subjected to the entire analytical procedure If <br /> � / the recovery of analytes from the matrix spike does not fall within specified control limits due to matrix <br /> C VLA interference,the LCS recovery is to be used to validate the batch <br /> **MS=Matrix Spike MSD=MS Duplicate, RPD=Relative%Difference <br /> Kevin Van Slambrook <br /> Project Manager Page 2 of 2 <br /> 6041944TUD <14> <br /> .qcl� <br />
The URL can be used to link to this page
Your browser does not support the video tag.