My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0002830
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARBOR
>
1805
>
2900 - Site Mitigation Program
>
PR0508461
>
ARCHIVED REPORTS_XR0002830
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2020 4:10:55 PM
Creation date
1/29/2020 3:36:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0002830
RECORD_ID
PR0508461
PE
2950
FACILITY_ID
FA0008092
FACILITY_NAME
CONTINENTAL GRAIN CO
STREET_NUMBER
1805
STREET_NAME
HARBOR
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14502005
CURRENT_STATUS
01
SITE_LOCATION
1805 HARBOR ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
yaw� li 11 <br /> • <br /> Soil samples collected from boring SB7 in the vicinity of the former UST on the northern part of <br /> the site contained low to nondetectable concentrations of TPHg Soil sample SB7-5 contained <br /> toluene, ethylbenzene, and total xylenes at concentrations of 0 018, 0 029, and 0 27 milligrams <br /> per kilogram (mg/kg), respectively Soil sample SB7-25 contained ethylbenzene and total xylenes <br /> at concentrations of 0 012 mg/kg and 0 027 mg/kg, respectively Soil samples SB7-10 and SB7- <br /> 15 contained no detectable concentrations of BTEX None of the soil samples collected from <br /> boring SB7 contained detectable concentrations of oxygenate fuel additives Soil sample SB7-5 <br /> contained total lead at an elevated concentration of 54 mg/kg Analytical results of soil samples <br /> are summarized in Table 1 Laboratory data sheets and chain-of-custody documentation is <br /> presented in Attachment 3 <br /> Groundwater Analytical Results <br /> Grab groundwater samples collected from borings SB 1, SB2, and SB3 contained detectable <br /> concentrations of TPHg The sample from boring SB2 also contained elevated concentrations of <br /> TPHd Grab groundwater samples collected from bonngs SB4, SB5, SB6, and SB7 did not <br /> contain detectable concentrations of TPHg The grab groundwater sample from boring SB4 also <br /> contained relatively low concentrations of TPHd Elevated concentrations of total lead were <br /> detected in the samples from borings SB2, SB4, and SB5 None of the grab groundwater samples <br /> collected detectable concentrations of BTEX or oxygenate fuel additives Analytical results of <br /> groundwater samples are summarized in Table 2 Laboratory data sheets and chain-of-custody <br /> documentation are contained in Attachment 4 <br /> CONCLUSIONS AND RECOMMENDATIONS <br /> Based on the analytical results and field observations, the soil and groundwater beneath the <br /> location of the former 10,000-gallon UST are impacted by TPHg TPHd, and lead Groundwater <br /> samples collected from borings SB4, SB5, and SB6 indicate that the extent of the plume is likely <br /> less than 80 feet from the former UST in the northwest, northeast, and southeast direction None <br /> of the soil or groundwater samples collected from the beneath the location of the former 10,000- <br /> gallon UST contained BTEX or oxygenate fuel additives <br /> Soil samples collected from beneath the former 750-gallon UST contained detectable <br /> concentrations of petroleum hydrocarbons The concentrations of toluene, ethylbenzene, xylenes, <br /> and TPHg were at their highest concentrations in the soil sample collected from 5 feet bgs <br /> Concentrations in the soil samples collected from 10 feet, 15 feet, and 25 feet bgs were barely <br /> above method detection limits The grab groundwater sample collected from beneath the former <br /> 750-gallon UST did not contain detectable concentrations of BTEX, TPHg, TPHd, or oxygenate <br /> fuel additives <br /> w 1625004eporWsum doe 4 <br /> • <br /> SMTH <br />
The URL can be used to link to this page
Your browser does not support the video tag.