My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_GROUNDWATER MONITORING REPORT - THIRD QUARTER 2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HANSEN
>
24550
>
2900 - Site Mitigation Program
>
PR0537774
>
ARCHIVED REPORTS_GROUNDWATER MONITORING REPORT - THIRD QUARTER 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2020 5:59:58 PM
Creation date
1/29/2020 4:36:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
GROUNDWATER MONITORING REPORT - THIRD QUARTER 2014
RECORD_ID
PR0537774
PE
2950
FACILITY_ID
FA0021779
FACILITY_NAME
FED X GROUND TRACY PROJECT
STREET_NUMBER
24550
Direction
S
STREET_NAME
HANSEN
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
24550 S HANSEN RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 3 of 15 <br /> tiff eurofins Work Order Narrative <br /> Calscience <br /> Work Order: 14-07-2003 Page 1 of 1 <br /> Condition Uoon Receipt <br /> Samples were received under Chain-of-Custody(COC)on 07/30/14. They were assigned to Work Order 14-07-2003. <br /> Unless otherwise noted on the Sample Receiving forms all samples were received in good condition and within the <br /> recommended EPA temperature criteria for the methods noted on the COC. The COC and Sample Receiving Documents are <br /> integral elements of the analytical report and are presented at the back of the report. <br /> Holdina Times: <br /> All samples were analyzed within prescribed holding times(HT)and/or in accordance with the Calscience Sample Acceptance <br /> Policy unless otherwise noted in the analytical report and/or comprehensive case narrative, if required. <br /> Any parameter identified in 40CFR Part 136.3 Table II that is designated as "analyze immediately"with a holding time of<= 15 <br /> minutes (40CFR-136.3 Table Il, footnote 4), is considered a"field"test and the reported results will be qualified as being <br /> received outside of the stated holding time unless received at the laboratory within 15 minutes of the collection time. <br /> Quality Control: <br /> All quality control parameters (QC)were within established control limits except where noted in the QC summary forms or <br /> described further within this report. <br /> Additional Comments: <br /> E <br /> Air-Sorbent-extracted air methods (EPA TO-4A, EPA TO-10, EPA TO-13A, EPA TO-17):Analytical results are converted from p <br /> mass/sample basis to mass/volume basis using client-supplied air volumes. <br /> New York NELAP air certification does not certify for all reported methods and analytes, reference the accredited items here: <br /> hftp://www.caiscience.com/PDF/New York.pdf <br /> Solid-Unless otherwise indicated, solid sample data is reported on a wet weight basis, not corrected for% moisture. All QC <br /> results are always reported on a wet weight basis. <br /> Subcontractor Information, <br /> Unless otherwise noted below(or on the subcontract form), no samples were subcontracted. <br /> 7440 Lincoln Way,Garden Grove,CA 92841-1427 • TEL:(714)895-5494 • FAX:(714)894-7501 <br />
The URL can be used to link to this page
Your browser does not support the video tag.