w) ' <br /> WORK REQUEST FORM <br /> Date of Request 02/16/05 Requested Completion Date 02/17/05 <br /> Prod Name Knowles Hammer Lane Proj No 95-013 <br /> Site Address 1140 West Hammer Lane, Stockton Ca <br /> Project Manager John Lane Field Tech A Scoma <br /> Client Contact Patrick Riddle Phone No 209-367-6992 <br /> Regulatory Cont ct Harlin Knoll Phone No 209-468-3442 <br /> Approval Completion Date 0�4 1,1Jo r or [AZ� <br /> Notify regulator and client 48 hours prior to arriving-on site <br /> Make sure all downhole equipment, including_pumps and W/L probe, are <br /> thoroughly deconned_prior to arriving on site <br /> Monitor DTW/DTB all wells In order <br /> MW9, 2, 3, 4, 1, 5 is the order <br /> Purge and sample wells MW2 and MW5 <br /> Sample for BTEX/T_P_H_g_ <br /> Samples to_Argon Labs Put on chain of custody that EDF reports are required. <br /> Wells are about 70 feet deep Water is at —39-40 feet Wells are two inch_ <br /> Drums are located in rear of store You can reuse the drums from wells 2,3,4,9 <br /> from last round as they were all ND <br /> Clearly label each drum as dedicated for particular well with date of pigged water <br /> and approximatealg lons per date <br /> Purge 3 to 5 casing volumes, BUT NO MORE Average purge volume will be <br /> approximately 10-14 gallons_ <br /> Store all drums in rear of store <br /> Take a detailed drum count <br /> • <br /> workreglknoham doe <br />