My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0002046
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1210
>
3500 - Local Oversight Program
>
PR0545245
>
ARCHIVED REPORTS_XR0002046
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2020 11:38:39 AM
Creation date
1/30/2020 10:50:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0002046
RECORD_ID
PR0545245
PE
3528
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
02
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HORIZON ENVIRONMENTAL INC. <br /> GROUNDWATER MONITORING <br /> FIELD METHODS AND PROCEDURES <br /> The following section describes field procedures that will be completed by Horizon Environmental <br /> Inc (Horizon) personnel in performance of the tasks involved with this project <br /> 10 HEALTH AND SAFETY PLAN <br /> Field work performed by Horizon and subcontractors at the site will be conducted according to guidelines <br /> established in a Site Health and Safety Plan (SHSP) The SHSP is a document that describes the hazards <br /> that may be encountered in the field and specifies protective equipment, work procedures and emergency <br /> information A copy of the SHSP will be at the site and available for reference by appropriate partses during <br /> work at the site <br /> 20 GROUNDWATER DEPTH EVALUATION <br /> Each monitoring well is opened and allowed to equalize to atmospheric pressure prior to sounding Depth-to- <br /> water is measured to the nearest 0 01-foot using an electronic, hand-held, water-level indicator The <br /> measuring point is the survey mark on the top of the well casing The tip of the probe is examined in order to <br /> determine the presence or absence of product sheen <br /> 30 MONITORING WELL PURGING & SAMPLING <br /> Prior to purging, a clean, transparent bailer is lowered into the well, and a sample of groundwater is hoisted to <br /> the surface The sample fluid is inspected for the presence of free-floating product on its surface Sampling <br /> activities conducted subsequent to the initial well development activity will be preceded by purging a minimum <br /> of three well volumes by hand-bailing or the use of an electrically-operated pump Purge water will be <br /> monitored for the parameters of temperature, pH, and electrical conductivity until stabilized <br /> If required, field readings for dissolved oxygen (d02), displayed in tenths of parts per million (ppm x 0 1), will be <br /> obtained utilizing Hanna Instruments' hand-held, HI-9142 Portable Dissolved Oxygen Meter Generally, higher d02 <br /> concentrations are expected in samples, which are unimpacted or marginally impacted by hydrocarbons than for <br /> samples collected from monitoring wells which yield hydrocarbon-impacted water <br /> A well is allowed to recharge to at least 80% of its prepurge volume prior to sampling If a well dewaters, it <br /> will be allowed to recharge for a minimum of one to two hours prior to sampling After the water level within <br /> the well has stabilized, a sample is collected within a dedicated, clean, disposable, plastic bailer lowered into <br /> the well and hoisted when filled <br /> 40 SAMPLE PREPARATION & TRANSPORT FOR LABORATORY ANALYSIS <br /> Samples will be transferred to airtight vials, chilled on ice, and transported to a California DoHS-certified <br /> laboratory for analysis Samples will be analyzed within the EPA-specified holding time for the requested <br /> analysis Each sample container submitted for analysis will have a label affixed to identify the job number, <br /> sample date, time of sample collection, and a sample number unique to that sample <br /> A chain-of-custody form will be used to record possession of the sample from time of collection to its arrival at <br /> the laboratory When the samples are shipped, the responsible technician or geologist relinquishes custody of <br /> the samples by signing the chain-of-custody form, noting the date and time The sample-control officer at the <br /> laboratory <br /> • verifies sample integrity, <br /> • confirms storage in the proper container, <br /> • recognizes that an adequate volume of fluid has been collected for the required analysis, <br /> • identifies the method of preservation, and <br /> • accepts custody for the laboratory when these conditions have been satisfied <br />
The URL can be used to link to this page
Your browser does not support the video tag.