Laserfiche WebLink
Horizon Environmental Inc TABLE 2 <br /> VET641t2 VAPOR TEST DATA <br /> Beacom Station 641 <br /> Stockton, Califomia <br /> TPH as_Gasoline Benzene <br /> TIME Sample INFLUENT SCFM INF INF EFF DEST INF INF EFF DEST <br /> SAMPLED No DPIVAC INF PPMV LBSID PPMV EFFIC PPMV LBSID PPMV EFFIC <br /> 11 00 AM Field Reading 016/104 303 15,210 154 5 100% NA NA NA NA <br /> 1145 AM A-0527-INF &EFF 014197 286 38,000 365 4 100% 1,700 14 0 094 100% <br /> 12 45 PM Field Reading 014/101 284 25,180 218 7 100% NA NA NA NA <br /> 145 PM Field Reading 020/124 326 22,120 242 8 100% NA NA NA NA <br /> 2 45 PM Field Reading 0201123 335 22,175 249 5 100% NA NA NA NA <br /> 3 45 PM Field Reading 020/123 334 22,150 248 7 100% NA NA NA NA <br /> 4 30 PM Field Reading 021/120 336 19,861 224 6 100% NA NA NA NA <br /> 5 30 PM Field Reading 021/123 334 23,200 262 5 100% NA NA NA NA <br /> 6 30 PM Field Reading 021/124 334 20,220 228 13 100% NA NA NA NA <br /> 7 30 PM Field Reading 0381112 46 21,280 328 77 100% NA NA NA NA <br /> 8 30 PM Field Reading 038/112 46 1 21,250 328 2050 90% 11 NA NA NA NA <br /> NOTES <br /> SCFM=Standard Cubic Feet per Minute <br /> LBSID=Pounds per Day <br /> INF=Influent <br /> EFF=Effluent <br /> PPMV=Parts per Million by Volume as reported in laboratory analysis <br /> DP= Differential pressure measured in inches of water <br /> VAC=Vacuum in inches of water <br /> Field Readings made with a Horiba Infrared Hydrocarbon Analyzer <br /> f <br /> VET641 t2 <br />