SITE HISTORY
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
1246
>
3500 - Local Oversight Program
>
PR0545264
>
SITE HISTORY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2020 3:04:20 PM
Creation date
1/30/2020 11:41:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE HISTORY
RECORD_ID
PR0545264
PE
3528
FACILITY_ID
FA0004964
FACILITY_NAME
CHEVRON USA (INACT)
STREET_NUMBER
1246
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15102203
CURRENT_STATUS
02
SITE_LOCATION
1246 E HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAOUIN-C^ PUBLIC HEALTH SERVICES/ENVIRONMENTAL HEAL7—)IVISION <br /> 1. v WORKSHEET FOR SITE CLOSURE EVALUATION DATE <br /> NAME OF FACILITY �` jJ <br /> SWEEPS COOP <br /> ADDRESS / l� a �ry,y` TANK ID # <br /> TANK SIZE /UUP FUEL TYPE <br /> II. GENERAL SITE HISTORY <br /> Is permit current? Yes No Permit # Facility Status Code r,3 Doc.Soi[/GW Cont Yes No <br /> Number of Tanks at facility Age of Tanks(if available) Type of Tank Steel rgl Sngl Dual <br /> Ill. TANK HISTORY _ <br /> Was Tank tested? Yes 71No failed precision test ? Yes No If yes, give date(s <br /> I I I I I E, <br /> i <br /> Was a repair made to the tank system? Yes No if yes, what was repaired? <br /> Was repair done under inspection? Yes No Were soil samples analyzed? Yes No BTXE TPH-G TPH-D Ph/EBB <br /> Type of failure/discharge catastrophic long-term leakage overfill unknown other: 1 <br /> IV. REMOVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> Soil Samples Received Yes No Depth to Ground water V,<) R, it Precipitation A-114 10-25 <br /> On-Site Weil(s) Yes No Number & Type Irr Doto �' ore S Score <br /> 1v <br /> Distance to wetl(s) from Tank ft; ft; f pts C 5 pts <br /> �f O !if <br /> ondition R condition <br /> V. Site Feature - teaching Potential Analysis s met E is met <br /> Minimum Depth to groundwater from the Snit Sample (feet) !l© 1-100 25-50\1 <br /> Fractures in subsurface (applies to foothills or mountain areas) Unknown Present <br /> Average Annual Precipitation (inches) xxxxxx <1O 9 10-25 xxxxxxx 26-40\2 <br /> Man-Made conduits which increase vertical migration <br /> of leachate (i.e., septic systems, water wells, ponds) None Unknown Present <br /> Unique site features: Recharge area, coarse soil, nearby wells. At least More than <br /> xxxNone one one <br /> xxx <br /> COLUMN TOTALS>»TOTAL POINTS > ; : <br /> i <br /> Sample Result: CB T X OR E) RANGE OF TOTAL POINTS 49 pts or more 41 - 48 pts 40 pts or less <br /> 81 T I x E B T X E <br /> MAXIMUM ALLOWABLE B-T-X-E LEVELS (PPM) 11501 50 50 .3 .3 1.1 1. NA\3 <br /> Sample Result: GASOLINE 1000 100 10 <br /> MAXIML14 ALLOWABLE TPH LEVELS (PPR) <br /> TAH DIESEL 10,000 1000 100 <br /> FOOTNOTES: mIf documented soil and/or ground water contamination is present, do not complete the teaching potential <br /> analysis. (i.e., site is currently on UGT Contamination List for sail or ground water.) <br /> \1 if depth is > 5 ft. and < 25 ft., score 0 points. If depth <4 ft., do not use table. <br /> \2 If precipitation is > 40 inches, score 0 points. <br /> \3 Levels for BTX&E are not applicable at a TPH concentration of 10 ppm (gasoline) or 100 ppm (dieset). 1 <br /> VI. STAFF RECOMMENDATION/CONCLUSION - w' _3 r— W <br /> 1. Are BTX & E or TPH Concentrations > ALL to Levels 'Yes No VO <br /> 2. Recommend Site Closure Yes No If Yes, Refer to Site Mitigation for Evaluation <br /> Vll. REVIEW EVALUATION - TO BE COMPLETED BY A SUPERVISOR/SENIOR l <br /> CONCUR WITH STAFF RECOMMENDATION FOR CLOSURE YES HO REFERRED TO SITE MITIGATION FOR EVALUATION TES Nd i <br /> i <br /> DATE REFERRED / / DATE CLOSURE LETTER MAILED / / I <br /> r <br /> i <br /> NAME OF <br /> EVALUATOR <br /> EH 23 80 (UGTWKSHT)\5/90 <br /> 1 <br /> ..1 <br />
The URL can be used to link to this page