Laserfiche WebLink
1• <br /> TABLE 2 <br /> Fuel Oxygenates Analytical Data <br /> • ARCO Service Station No. 548 <br /> 1612 Hammer Lane, Stockton, California <br /> Well TBA MtBE DIPE ETBE TAME 1,2-DCA Ethanol <br /> Number Date pg/L pg/L pg/L Eig/L pg/L _Ng/L N L <br /> VW-5D 12/13/2001 <50[3] 67[3] <5.0[3] <5.0[3] <5.0[3] 83[3] NA <br /> 3/12/2002 890 <2.5[3] <2.5[3] <2.5[3] <2.5[3] <2.5[3] NA <br /> 9/9/2002 290 <5 <5 <5 <5 <5 NA <br /> 12/4/2002 <4,000 <100 <100 <100 <100 <100 NA <br /> 3/3/2003 <200 <5 <5 <5 <5 <5 <1000(a) <br /> 6/3/2003 <40 <1.0 <2.0 <2.0 <2.0 <1.0 <200 <br /> 9/18/2003 Not Sampled <br /> 12/8/2003 Not Sampled <br /> Notes: <br /> O)iygenates analyzed by USEPA Method 8260. <br /> < <=Below detection limit for analytical methods used. <br /> (a) (a)5/23/03 Revised analytical report replaces the 3126103 report to correct the reporting limit for Ethanol from 40 ug/L to 100 ug/L. <br /> 1,2-DCA 1,2-DCA=1,2-Dichloroethane <br /> DIPE DIPE=Di-isopropyl ether. <br /> EtBE ETRE=Ethyl Tert butyl ether. <br /> MtBE MtBE=Methyl tort-butyl ether. <br /> mg1L mglL=micrograms per liter. <br /> NA NA=not analyzed. <br /> TAME TAME=Tert amyl methyl ether. <br /> TBA TBA=Teri butyl alcohol. <br /> [1]This sample was analyzed outside EPA recommended holding time. <br /> 12]The opening calibration verification standard was outside acceptance limits by<30/6. Although the Lab Control Sample verified the <br /> accuracy of this batch,this should be considered in evaluating the data for its intended purpose. <br /> [3]The sample was diluted due to the presence of high levels of non-target analytes resulting in elevated reporting limits. <br /> [4]The sample was diluted due to the presence of high levels of target analytes resulting in elevated reporting limits. Beginning <br /> third quarter 2002,the data quality analyses are presented in the text. <br /> Data Qualifier Definitions: <br /> U The analyte was analyzed for,but was not detected above the sample reporting limit. <br /> J The analyte was positively identified;the associated numerical value is the approximate concentration of the analyte in the sample. <br /> N The analysis indicates the presence of an analyte for which there is presumptive evidence to make a"tentative identification." <br /> NJ The analysis indicates the presence of an analyte that has been`tentatively identified'and the associated numerical value <br /> represents its approximate concentration. <br /> UJ The analyte was not detected above the reported sample reporting limit. However,the reported reporting limit is approximate and <br /> may or may not represent the actual limit of quantitation necessary to accurately and precisely measure the analyte in the sample. <br /> R The sample results are rejected due to identification or other analytical issues. <br /> ND Not detected above reported detection limit <br /> K:IWprocessW5 BP ARC01005481Quarterlyl4 QTR 0410548 OMR 4003 Page 4 014 <br />