My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0002996
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1612
>
3500 - Local Oversight Program
>
PR0545246
>
ARCHIVED REPORTS_XR0002996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2020 7:53:07 PM
Creation date
1/30/2020 3:20:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0002996
RECORD_ID
PR0545246
PE
3528
FACILITY_ID
FA0003611
FACILITY_NAME
PARKWOODS GAS & FOOD
STREET_NUMBER
1612
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07728002
CURRENT_STATUS
02
SITE_LOCATION
1612 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ t <br /> UM <br /> IN IF C Eff i��11fll Ef p1j, <br /> r FEB 1 4 2005 <br /> February 10, 2005 ENVIRONMENT HEALTH <br /> i <br /> PERMIT/SERVICES <br /> I <br /> Ms.Lori Duncan 00548 <br /> San Joaquin County Environmental Health Department 06.a4 <br /> ~� 304 East Weber Avenue,Third Floor <br /> Stockton, California 95201 <br /> Re: Groundwater Monitoring Well Installation Report <br /> Former ARCO Station No. 548 <br /> 1612 W. Hammer Lane <br /> r. <br /> Stockton, California 95209 <br /> Dear Ms. Duncan: <br /> URS Corporation Americas (URS), on behalf of Atlantic Richfield Company (ARCO - a BP affiliated <br /> company) has prepared this report to document monitoring well installation activities conducted at the <br /> former ARCO Station No. 548 located at 1612 W. Hammer Lane in Stockton, California (site) (Figure <br /> 1). One shallow monitoring well and one deep monitoring well were installed to assess the lateral and <br /> ` vertical extent of petroleum-impacted groundwater. This investigation was conducted in response to the <br /> San Joaquin County Environmental Health Department (SJCEHD) letter dated June 21, 2004 <br /> (Attachment A), which requests an investigation of the vertical extent of impacted groundwater and the <br /> installation of monitoring wells that will intercept first groundwater. The fieldwork was performed as <br /> described in the Workplan for Additional Assessment dated August 27, 2004, which was approved by <br /> SJCEHD in a letter dated October 4, 2004 (Attachment A). The SJCEHD boring permits and a City of <br /> Stockton encroachment permit are included in Attachment A. <br /> SITE BACKGROUND <br /> The site is Iocated at the southwest corner of the intersection of W. Hammer Lane and Brentwood Drive <br /> in Stockton, California (Figures. I and 2). The site formerly operated as an ARCO service station. <br /> Currently, the site is operating as a Valero retail gasoline station. Current site structures include four <br /> underground storage tanks (USTs), two pump islands, and a convenience store. <br /> ' Site investigations have been ongoing since October 1990. A total of six groundwater monitoring wells <br /> (MW-1 through MW-6), six soil vapor extraction (SVE) wells (VW-1 through VW-5S and VW-51)), <br /> and three air sparge (AS) wells (AS-1, AS-2, and AS-3) are installed at the site. Well locations are <br /> ! shown in Figure 2. The investigations indicate that hydrocarbon-impacted soil is limited to the <br /> proximity of the UST complex. In February 1998, four gasoline USTs of various capacities and their <br /> associated piping were removed and replaced. <br /> i <br /> URS Corporation <br /> Crown Corporate Center <br /> 2870 Gateway Oaks Drive,Suite 300 <br /> Sacramento,CA 95833 <br /> Tel:916.679.2000 <br /> Fax:916.679.2900 KAWprocessV5 BP ARCM054812004 well instalAAdd Site Assess Rpt 04.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.