Laserfiche WebLink
ub" <br /> "N' KE no rI <br /> Table 5 <br /> Fuel Oxygenates Analytical Data <br /> ARCO Service Station No. 548 <br /> 1612 W. Hammer Lane, Stockton, CA <br /> Notes: <br /> —=not measured or analyzed <br /> <=below detection limit for analytical methods used <br /> pglL=micrograms per liter <br /> 1,2-DCA=1,2-dichloroethane <br /> DIPE=di-isopropyl ether <br /> EtBE=ethyl tertiary butyl ether <br /> MtBE=methyl tert-butyl ether <br /> MW=monitoring well <br /> NA=not analyzed <br /> TAME=tertiary amyl methyl ether <br /> TBA=tertiary butyl alcohol <br /> U.S. EPA=United States Environmental Protection Agency <br /> VW=vapor well <br /> [i]This sample was analyzed outside U.S.EPA recommended holding time. <br /> [2]The opening calibration verification standard was outside acceptance limits by<3%. Although the laboratory control sample verified the accuracy of <br /> this batch,this should be considered in evaluating the data for its intended purpose. <br /> [3]The sample was diluted because the presence of high levels of non-target analytes resulted in elevated reporting limits. <br /> [4]The sample was diluted because the presence of high levels of target analytes resulted in elevated reporting limits. <br /> Data quality analyses are presented in the text beginning in the third quarter of 2002. <br /> 3/11/2004-VW-5S and VW-5D data are rejected because of a discrepancy during sampling. <br /> Oxygenates analyzed by U.S.EPA Method 82608. <br /> Data Qualifier Definitions: <br /> U=The analyte was analyzed for,but was not detected above the sample reporting limit. <br /> J=The analyte was positively identified;the associated numerical value is the approximate concentration of the analyte in the sample. <br /> N=The analysis indicates the presence of an analyte for which there is presumptive evidence to make a tentative identification. <br /> NJ=The analysis indicates the presence of an analyte that has been tentatively identified,and the associated numerical value represents its approximate concentration. <br /> UJ=The analyte was not detected above the reported sample reporting limit. However,the reported reporting limit is approximate and may or may not represent the actual limit of quantitation <br /> necessary to accurately and precisely measure the analyte in the sample. <br /> R=The sample results are rejected because of identification or other analytical issues. <br /> ND=Not detected above reported detection limit. <br /> Report Date:August 25,2004 Page 7 of 7 <br />