i <br /> i <br /> A Delta technician conducted seven site visits to optimize and maintain the SVEIAS system. <br /> • Approximately 168 lbs of TPHG as gasoline was removed during the third quarter 2001, and a cumulative <br /> mass of 1,030.43 lbs since startup (09128100). Influent air concentrations have increased during the last <br /> sampling event (915101) of the third quarter. The increase in concentrations is probably due to the <br /> decrease in groundwater elevations of approximately 2.5 feet. The compressor for air sparging was shut <br /> down due neighbors complaining of the noise durin the was restarted a er ins a m a <br /> Amer to operate betw 0 hrs. Delta will optimize the operation o e system by <br /> increasing ows, and therefore influent concentrations, by changing the vacuum and flows from the <br /> individual wells. The SVE system was in compliance with San Joaquin Valley Unified Air Pollution Control <br /> District permit to operate. <br /> ATTACHMENTS: <br /> • Table 1 Groundwater Monitoring Data <br /> • Table 2 Groundwater Analytical Results for Oxygenates and Additional Compounds <br /> • Table 3 Floating Product Monitoring Summary, Well VW-5D <br /> • Table 4 Operational Uptime Information of the Soil Vapor Extraction System <br /> • Table 5 Flow Rates and Analytical Results of Air Sample Analyses <br /> • Table 6 Extraction and Emission Rates <br /> • Figure 1 Site Topographic Map <br /> • Figure 2 Groundwater Elevation Contours, 3" Quarter 2001 <br /> • Figure 3 Groundwater Analytical Summary 3`d Quarter 2001 <br /> • Figure 4 Influent Concentrations vs Time <br /> • Figure 5 Cumulative Mass Removed vs Time <br /> • Appendix A Field Data Sheets <br /> • Appendix B Sampling and Analysis Procedures <br /> + Appendix C Certified Analytical Reports and Chain-of-Custody Records <br /> i <br /> PAARC0105481QTRL.Y1200I\Arco_0548_3Q01Report.doc Delta <br />